  Datasheet File OCR Text:
 xr
MAY 2005
XR16L2752
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REV. 1.2.1
GENERAL DESCRIPTION
The XR16L27521 (2752) is a low voltage dual universal asynchronous receiver and transmitter (UART) with 5 Volt tolerant inputs. The device operates from 2.25 to 5.5 Volt supply range and is pin-to-pin compatible to Exar's ST16C2552 and XR16C2852. The 2752 register set is compatible to the ST16C2552 and the XR16C2852 enhanced features. It supports the Exar's enhanced features of 64 bytes of TX and RX FIFOs, programmable FIFO trigger level and FIFO level counters, automatic hardware (RTS/CTS) and software flow control, automatic RS-485 half duplex direction control output and a complete modem interface. Onboard registers provide the user with operational status and data error flags. An internal loopback capability allows system diagnostics. Independent programmable baud rate generators are provided in each channel to select data rates up to 6.25 Mbps at 5 Volt and 8X sampling. The 2752 is available in the 44-pin PLCC package.
NOTE: 1 Covered by U.S. Patent #5,649,122 and #5,949,787
FEATURES
* 2.25 to 5.5 Volt Operation * 5 Volt Tolerant Inputs * Pin-to-pin compatible to Exar's ST16C2552 and
XR16C2852
* Larger FIFO version of PC16C552 * Two independent UART channels

APPLICATIONS
Reg set compatible to 16C2552 and 16C2852 Up to 6.25 Mbps at 5 Volt, 4 Mbps at 3.3 Volt and 3 Mbps at 2.5 Volt with 8X sampling rate Transmit and Receive FIFOs of 64 bytes Programmable TX and RX FIFO Trigger Levels Transmit and Receive FIFO Level Counters Automatic Hardware (RTS/CTS) Flow Control Selectable Auto RTS Flow Control Hysteresis Automatic Software (Xon/Xoff) Flow Control Automatic RS-485 Half-duplex Direction Control Output via RTS# Wireless Infrared (IrDA 1.0) Encoder/Decoder Automatic sleep mode Full modem interface
* Portable Appliances * Telecommunication Network Routers * Ethernet Network Routers * Cellular Data Devices * Factory Automation and Process Controls
FIGURE 1. XR16L2752 BLOCK DIAGRAM
* Alternate Function Register * Device Identification and Revision * Crystal oscillator or external clock input * Industrial and commercial temperature ranges * 44-PLCC package
A2:A0 D7:D0 IOR# IOW# CS# CHSEL INTA INTB TXRDYA# TXRDYB# MFA#
(OP2A#, BAUDOUTA#, or RXRDYA#)
*5 Volt Tolerant Inputs (Except External Clock Input) UART Channel A UART Regs BRG 8-bit Data Bus Interface 64 Byte TX FIFO TX & RX IR ENDEC
2.25 V to 5.5 V VCC GND
TXA (or TXIRA)
64 Byte RX FIFO
RXA (or RXIRA) TXB (or TXIRB) RXB (or RXIRB) XTAL1 XTAL2 CTS#A/B, RI#A/B, CD#A/B, DSR#A/B DTR#A/B, RTS#A/B
2752BLK
UART Channel B (same as Channel A)
MFB#
(OP2B#, BAUDOUTB#, or RXRDYB#)
Crystal Osc/Buffer Modem Control Logic
Reset
Exar Corporation 48720 Kato Road, Fremont CA, 94538 * (510) 668-7000 * FAX (510) 668-7017 * www.exar.com
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO FIGURE 2. PIN OUT ASSIGNMENT
xr
REV. 1.2.1
TXRDYA#
DSRA# 41
44
43
42
40
6
5
4
3
2
1
CTSA#
CDA#
RIA#
VCC
D4
D3
D2
D1
D0
D5 D6 D7 A0 XTAL1
7 8 9 10 11
39 38 37 36
RXA TXA DTRA# RTSA#
GND 12 XTAL2 A1 13 14
XR16L2752 44-pin PLCC
35 MFA# 34 33 32 31 INTA VCC TXRDYB# RIB#
A2 15 CHSEL 16 INTB 17 CS# 18 MFB# 19 IOW# 20 RESET 21 GND 22 RTSB# 23 IOR# 24 RXB 25 TXB 26 DTRB# 27 CTSB# 28
30 CDB# 29 DSRB#
ORDERING INFORMATION
PART NUMBER XR16L2752CJ XR16L2752IJ PACKAGE 44-Lead PLCC 44-Lead PLCC OPERATING TEMPERATURE RANGE 0C to +70C -40C to +85C DEVICE STATUS Active Active
2
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
PIN DESCRIPTIONS
Pin Description
NAME 44-PLCC PIN # 15 14 10 9 8 7 6 5 4 3 2 24 TYPE DESCRIPTION
DATA BUS INTERFACE A2 A1 A0 D7 D6 D5 D4 D3 D2 D1 D0 IOR# I Address data lines [2:0]. These 3 address lines select one of the internal registers in UART channel A/B during a data bus transaction. Data bus lines [7:0] (bidirectional).
I/O
I
Input/Output Read Strobe (active low). The falling edge instigates an internal read cycle and retrieves the data byte from an internal register pointed to by the address lines [A2:A0]. The data byte is placed on the data bus to allow the host processor to read it on the rising edge. Input/Output Write Strobe (active low). The falling edge instigates an internal write cycle and the rising edge transfers the data byte on the data bus to an internal register pointed by the address lines. UART chip select (active low). This function selects channel A or B in accordance with the logical state of the CHSEL pin. This allows data to be transferred between the user CPU and the 2752. Channel Select - UART channel A or B is selected by the logical state of this pin when the CS# pin is a logic 0. A logic 0 on the CHSEL selects the UART channel B while a logic 1 selects UART channel A. Normally, CHSEL could just be an address line from the user CPU such as A4. Bit-0 of the Alternate Function Register (AFR) can temporarily override CHSEL function, allowing the user to write to both channel register simultaneously with one write cycle when CS# is low. It is especially useful during the initialization routine. UART channel A Interrupt output (active high). A logic high indicates channel A is requesting for service. For more details, see Figures 18- 23. UART channel B Interrupt output (active high). A logic high indicates channel B is requesting for service. For more details, see Figures 18- 23.
IOW#
20
I
CS#
18
I
CHSEL
16
I
INTA INTB TXRDYA# TXRDYB#
34 17 1 32
O O O O
UART channel A Transmitter Ready (active low). The output provides the TX FIFO/THR status for transmit channel A. See Table 2.
UART channel B Transmitter Ready (active low). The output provides the TX FIFO/ THR status for transmit channel B. See Table 2. UART channel A Transmit Data or infrared encoder data. Standard transmit and receive interface is enabled when MCR[6] = 0. In this mode, the TX signal will be HIGH during reset or idle (no data). Infrared IrDA transmit and receive interface is enabled when MCR[6] = 1. In the Infrared mode, the inactive state (no data) for the Infrared encoder/decoder interface is LOW. If it is not used, leave it unconnected.
MODEM OR SERIAL I/O INTERFACE TXA 38 O
3
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO Pin Description
NAME RXA 44-PLCC PIN # 39 TYPE I DESCRIPTION
xr
REV. 1.2.1
UART channel A Receive Data or infrared receive data. Normal receive data input must idle HIGH. The infrared receiver pulses typically idles LOW but can be inverted by software control prior going in to the decoder, see MCR[6] and FCTR[2]. If this pin is not used, tie it to VCC or pull it high via a 100k ohm resistor. UART channel A Request-to-Send (active low) or general purpose output. This output must be asserted prior to using auto RTS flow control, see EFR[6], MCR[1], FCTR[1:0], EMSR[5:4] and IER[6]. For auto RS485 half-duplex direction control, see FCTR[3] and EMSR[3]. UART channel A Clear-to-Send (active low) or general purpose input. It can be used for auto CTS flow control, see EFR[7], and IER[7]. This input should be connected to VCC when not used. UART channel A Data-Terminal-Ready (active low) or general purpose output. If this pin is not used, leave it unconnected. UART channel A Data-Set-Ready (active low) or general purpose input. This input should be connected to VCC when not used. This input has no effect on the UART. UART channel A Carrier-Detect (active low) or general purpose input. This input should be connected to VCC when not used. This input has no effect on the UART. UART channel A Ring-Indicator (active low) or general purpose input. This input should be connected to VCC when not used. This input has no effect on the UART. Multi-Function Output Channel A. This output pin can function as the OP2A#, BAUDOUTA#, or RXRDYA# pin. One of these output signal functions can be selected by the user programmable bits 1-2 of the Alternate Function Register (AFR). These signal functions are described as follows: 1) OP2A# - When OP2A# (active low) is selected, the MF# pin is LOW when MCR bit3 is set to a logic 1 (see MCR bit-3). MCR bit-3 defaults to a logic 0 condition after a reset or power-up. 2) BAUDOUTA# - When BAUDOUTA# function is selected, the 16X Baud rate clock output is available at this pin. 3) RXRDYA# - RXRDYA# (active low) is intended for monitoring DMA data transfers. See Table 2 for more details.
RTSA#
36
O
CTSA#
40
I
DTRA# DSRA# CDA# RIA# MFA#
37 41 42 43 35
O I I I O
TXB
26
O
UART channel B Transmit Data or infrared encoder data. Standard transmit and receive interface is enabled when MCR[6] = 0. In this mode, the TX signal will be HIGH during reset or idle (no data). Infrared IrDA transmit and receive interface is enabled when MCR[6] = 1. In the Infrared mode, the inactive state (no data) for the Infrared encoder/decoder interface is LOW. If it is not used, leave it unconnected. UART channel B Receive Data or infrared receive data. Normal receive data input must idle HIGH. The infrared receiver pulses typically idles LOW but can be inverted by software control prior going in to the decoder, see MCR[6] and FCTR[2]. If this pin is not used, tie it to VCC or pull it high via a 100k ohm resistor. UART channel B Request-to-Send (active low) or general purpose output. This port must be asserted prior to using auto RTS flow control, see EFR[6], MCR[1], FCTR[1:0], EMSR[5:4] and IER[6]. For auto RS485 half-duplex direction control, see FCTR[3] and EMSR[3].
RXB
25
I
RTSB#
23
O
4
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
Pin Description
NAME CTSB# 44-PLCC PIN # 28 TYPE I DESCRIPTION UART channel B Clear-to-Send (active low) or general purpose input. It can be used for auto CTS flow control, see EFR[7], and IER[7]. This input should be connected to VCC when not used. UART channel B Data-Terminal-Ready (active low) or general purpose output. If this pin is not used, leave it unconnected. UART channel B Data-Set-Ready (active low) or general purpose input. This input should be connected to VCC when not used. This input has no effect on the UART. UART channel B Carrier-Detect (active low) or general purpose input. This input should be connected to VCC when not used. This input has no effect on the UART. UART channel B Ring-Indicator (active low) or general purpose input. This input should be connected to VCC when not used. This input has no effect on the UART. Multi-Function Output Channel B. This output pin can function as the OP2B#, BAUDOUTB#, or RXRDYB# pin. One of these output signal functions can be selected by the user programmable bits 1-2 of the Alternate Function Register (AFR). These signal functions are described as follows: 1) OP2B# - When OP2B# (active low) is selected, the MF# pin is LOW when MCR bit3 is set HIGH (see MCR bit-3). MCR bit-3 defaults to a logic 0 condition after a reset or power-up. 2) BAUDOUTB# - When BAUDOUTB# function is selected, the 16X Baud rate clock output is available at this pin. 3) RXRDYB# - RXRDYB# (active low) is intended for monitoring DMA data transfers. See Table 2 for more details. ANCILLARY SIGNALS XTAL1 XTAL2 RESET 11 13 21 I O I Crystal or external clock input. Caution: this input is not 5V tolerant. Crystal or buffered clock output. Reset (active high) - A longer than 40 ns HIGH pulse on this pin will reset the internal registers and all outputs. The UART transmitter output will be held HIGH, the receiver input will be ignored and outputs are reset during reset period (see External Reset Conditions). 2.25 to 5.5V power supply. All input pins, except XTAL1, are 5V tolerant. Power supply common, ground.
DTRB# DSRB# CDB# RIB# MFB#
27 29 30 31 19
O I I I O
VCC GND
44, 33 22, 12
Pwr Pwr
Pin type: I=Input, O=Output, I/O= Input/output, OD=Output Open Drain.
5
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO 1.0 PRODUCT DESCRIPTION
xr
REV. 1.2.1
The XR16L2752 (2752) integrates the functions of 2 enhanced 16C550 Universal Asynchronous Receiver and Transmitter (UART). Each UART is independently controlled having its own set of device configuration registers. The configuration registers set is 16550 UART compatible for control, status and data transfer. Additionally, each UART channel has 64-bytes of transmit and receive FIFOs, automatic RTS/CTS hardware flow control with hysteresis control, automatic Xon/Xoff and special character software flow control, programmable transmit and receive FIFO trigger levels, FIFO level counters, infrared encoder and decoder (IrDA ver 1.0), programmable baud rate generator with a prescaler of divide by 1 or 4, and data rate up to 6.25 Mbps with 8X sampling clock rate or 3.125 Mbps in the 16X rate. The XR16L2752 is a 2.25 to 5.5V device with 5 volt tolerant inputs. The 2752 is fabricated with an advanced CMOS process. Enhanced Features The 2752 DUART provides a solution that supports 64 bytes of transmit and receive FIFO memory, instead of 128 bytes provided in the XR16C2852 and 16 bytes in the ST16C2552. The 2752 is designed to work with low supply voltage and high performance data communication systems, that require fast data processing time. Increased performance is realized in the 2752 by the larger transmit and receive FIFOs, FIFO trigger level control, FIFO level counters and automatic flow control mechanism. This allows the external processor to handle more networking tasks within a given time. For example, the ST16C2552 with a 16 byte FIFO, unloads 16 bytes of receive data in 1.53 ms (This example uses a character length of 11 bits, including start/stop bits at 115.2 Kbps). This means the external CPU will have to service the receive FIFO at 1.53 ms intervals. However with the 64 byte FIFO in the 2752, the data buffer will not require unloading/loading for 6.1 ms. This increases the service interval giving the external CPU additional time for other applications and reducing the overall UART interrupt servicing time. In addition, the programmable FIFO level trigger interrupt and automatic hardware/software flow control is uniquely provided for maximum data throughput performance especially when operating in a multi-channel system. The combination of the above greatly reduces the CPU's bandwidth requirement, increases performance, and reduces power consumption. The 2752 supports a half-duplex output direction control signaling pin, RTS# A/B, to enable and disable the external RS-485 transceiver operation. It automatically switches the logic state of the output pin to the receive state after the last stop-bit of the last character has been shifted out of the transmitter. After receiving, the logic state of the output pin switches back to the transmit state when a data byte is loaded in the transmitter. The auto RS-485 direction control pin is not activated after reset. To activate the direction control function, user has to set FCTR Bit-3 to "1". This pin is normally high for receive state, low for transmit state. Data Rate The 2752 is capable of operation up to 3.125 Mbps at 5V with 16X internal sampling clock rate, and 6.25 Mbps at 5V with 8X sampling clock rate. The device can operate with an external 24 MHz crystal on pins XTAL1 and XTAL2, or external clock source of up to 50 MHz on XTAL1 pin. With a typical crystal of 14.7456 MHz and through a software option, the user can set the prescaler bit for data rates of up to 1.84 Mbps. The rich feature set of the 2752 is available through the internal registers. Automatic hardware/software flow control, selectable transmit and receive FIFO trigger levels, selectable TX and RX baud rates, infrared encoder/decoder interface, modem interface controls, and a sleep mode are all standard features. Following a power on reset or an external reset, the 2752 is software compatible with previous generation of UARTs 16C2552 and 16C2852.
6
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
2.0 FUNCTIONAL DESCRIPTIONS 2.1 CPU Interface The CPU interface is 8 data bits wide with 3 address lines and control signals to execute data bus read and write transactions. The 2752 data interface supports the Intel compatible types of CPUs and it is compatible to the industry standard 16C550 UART. No clock (oscillator nor external clock) is required to operate a data bus transaction. Each bus cycle is asynchronous using CS#, IOR# and IOW# signals. Both UART channels share the same data bus for host operations. The data bus interconnections are shown in Figure 3 FIGURE 3. XR16L2750 DATA BUS INTERCONNECTIONS
D0 D1 D2 D3 D4 D5 D6 D7 A0 A1 A2 IO R # IO W # UART_CS# UART_CHSEL U A R T _ IN T A U A R T _ IN T B TXRDYA# (R X R D Y A # ) TXRDYB# (R X R D Y B # ) UART_RESET
D0 D1 D2 D3 D4 D5 D6 D7 A0 A1 A2 IO R # IO W # CS# CHSEL IN T A IN T B TXRDYA# (R X R D Y A # ) TXRDYB# (R X R D Y B # ) RESET
VCC TXA RXA DTRA# RTSA# CTSA# DSRA#
VCC
UART Channel A
S e ria l In te rfa c e o f R S -2 3 2 , R S -4 8 5
CDA# R IA # (O P 2 A # ) (B A U D O U T A # ) TXB RXB UART Channel B DTRB# RTSB# CTSB# DSRB# CDB# R IB # (O P 2 B # ) (B A U D O U T B # ) GND 2 7 5 0 in t
S e ria l In te rfa c e o f R S -2 3 2 , R S -4 8 5
P in s in p a re n th e s e s b e c o m e a v a ila b le th ro u g h th e M F # p in . M F # A /B b e c o m e s R X R D Y # A /B w h e n A F R [2 :1 ] = '1 0 '. M F # A /B b e c o m e s O P 2 # A /B w h e n A F R [2 :1 ] = '0 0 '. M F # A /B b e c o m e s B A U D O U T # A /B w h e n A F R [1 :0 ] = '0 1 '.
2.2
5-Volt Tolerant Inputs
The 2752 can accept up to 5V inputs even when operating at 3.3V or 2.5V. But note that if the 2752 is operating at 2.5V, its VOH may not be high enough to meet the requirements of the VIH of a CPU or a serial transceiver that is operating at 5V. Caution: XTAL1 is not 5 volt tolerant. 2.3 Device Reset The RESET input resets the internal registers and the serial interface outputs in both channels to their default state (see Table 16). An active high pulse of longer than 40 ns duration will be required to activate the reset function in the device. 2.4 Device Identification and Revision The XR16L2752 provides a Device Identification code and a Device Revision code to distinguish the part from other devices and revisions. To read the identification code from the part, it is required to set the baud rate generator registers DLL and DLM both to 0x00. Now reading the content of the DLM will provide 0x0A for the XR16L2752 and reading the content of DLL will provide the revision of the part; for example, a reading of 0x01 means revision A. 2.5 Channel A and B Selection The UART provides the user with the capability to bi-directionally transfer information between an external CPU and an external serial communication device. A logic 0 on chip select pin (CS#) allows the user to select the UART and then using the channel select (CHSEL) pin, the user can select channel A or B to configure, send transmit data and/or unload receive data to/from the UART. Individual channel select functions are shown in Table 1.
7
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO TABLE 1: CHANNEL A AND B SELECT
CS# 1 0 0 CHSEL X 1 0 FUNCTION UART de-selected Channel A selected Channel B selected
xr
REV. 1.2.1
2.6
Channel A and B Internal Registers
Each UART channel in the 2752 has a set of enhanced registers for control, monitoring and data loading and unloading. The configuration register set is compatible to those already available in the standard single 16C550 and dual ST16C2550. These registers function as data holding registers (THR/RHR), interrupt status and control registers (ISR/IER), a FIFO control register (FCR), receive line status and control registers (LSR/ LCR), modem status and control registers (MSR/MCR), programmable data rate (clock) divisor registers (DLL/ DLM), and a user accessible Scratchpad Register (SPR). Beyond the general 16C2550 features and capabilities, the 2752 offers enhanced feature registers (AFR, EMSR, FLVL, EFR, Xon/Xoff 1, Xon/Xoff 2, FCTR, TRG, FC) that provide automatic RTS and CTS hardware flow control, Xon/Xoff software flow control, automatic RS-485 half-duplex direction output enable/disable, FIFO trigger level control, FIFO level counters, and simultaneous writes to both channels. All the register functions are discussed in full detail later in "Section 3.0, UART INTERNAL REGISTERS" on page 20. 2.7 Simultaneous Write to Channel A and B During a write mode cycle, the setting of Alternate Function Register (AFR) bit-0 to a logic 1 will override the CHSEL selection and allows a simultaneous write to both UART channel sections. This functional capability allow the registers in both UART channels to be modified concurrently, saving individual channel initialization time. Caution should be considered, however, when using this capability. Any in-process serial data transfer may be disrupted by changing an active channel's mode. 2.8 DMA Mode The device does not support direct memory access. The DMA Mode (a legacy term) in this document doesn't mean "direct memory access" but refers to data block transfer operation. The DMA mode affects the state of the RXRDY# A/B (MF# A/B becomes RXRDY# A/B output when AFR[2:1] = `10') and TXRDY# A/B output pins. The transmit and receive FIFO trigger levels provide additional flexibility to the user for block mode operation. The LSR bits 5-6 provide an indication when the transmitter is empty or has an empty location(s) for more data. The user can optionally operate the transmit and receive FIFO in the DMA mode (FCR bit-3=1). When the transmit and receive FIFO are enabled and the DMA mode is disabled (FCR bit-3 = 0), the 2752 is placed in single-character mode for data transmit or receive operation. When DMA mode is enabled (FCR bit3 = 1), the user takes advantage of block mode operation by loading or unloading the FIFO in a block sequence determined by the programmed trigger level. In this mode, the 2752 sets the TXRDY# pin when the transmit FIFO becomes full, and sets the RXRDY# pin when the receive FIFO becomes empty. The following table shows their behavior. Also see Figures 18 through 23. TABLE 2: TXRDY# AND RXRDY# OUTPUTS IN FIFO AND DMA MODE
PINS FCR BIT-0=0 (FIFO DISABLED) FCR BIT-0=1 (FIFO ENABLED) FCR Bit-3 = 0 (DMA Mode Disabled) RXRDY# A/B LOW = 1 byte. HIGH = no data. LOW = at least 1 byte in FIFO. HIGH = FIFO empty. FCR Bit-3 = 1 (DMA Mode Enabled) HIGH to LOW transition when FIFO reaches the trigger level, or time-out occurs. LOW to HIGH transition when FIFO empties. LOW = FIFO has at least 1 empty location. HIGH = FIFO is full.
TXRDY# A/B LOW = THR empty. LOW = FIFO empty. HIGH = byte in THR. HIGH = at least 1 byte in FIFO.
8
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
2.9
INTA and INTB Outputs
The INTA and INTB interrupt output changes according to the operating mode and enhanced features setup. Table 3 and 4 summarize the operating behavior for the transmitter and receiver. Also see Figures 18 through 23. TABLE 3: INTA AND INTB PINS OPERATION FOR TRANSMITTER
Auto RS485 Mode INTA/B Pin INTA/B Pin NO YES FCR BIT-0 = 0 (FIFO DISABLED) LOW = a byte in THR HIGH = THR empty LOW = a byte in THR HIGH = transmitter empty FCR BIT-0 = 1 (FIFO ENABLED) LOW = FIFO above trigger level HIGH = FIFO below trigger level or FIFO empty LOW = FIFO above trigger level HIGH = FIFO below trigger level or transmitter empty
TABLE 4: INTA AND INTB PIN OPERATION FOR RECEIVER
FCR BIT-0 = 0 (FIFO DISABLED) INTA/B Pin LOW = no data HIGH = 1 byte FCR BIT-0 = 1 (FIFO ENABLED) LOW = FIFO below trigger level HIGH = FIFO above trigger level
2.10
Crystal Oscillator or External Clock Input
The 2752 includes an on-chip oscillator (XTAL1 and XTAL2) to produce a clock for both UART sections in the device. The CPU data bus does not require this clock for bus operation. The crystal oscillator provides a system clock to the Baud Rate Generators (BRG) section found in each of the UART. XTAL1 is the input to the oscillator or external clock buffer input with XTAL2 pin being the output. For programming details, see "Programmable Baud Rate Generator." FIGURE 4. TYPICAL OSCILLATOR CONNECTIONS
XTAL1
XTAL2 R1 0-120 (Optional) 1.8432 MHz to 24 MHz
R2 500 K - 1 M Y1 C1 22-47 pF C2 22-47 pF
9
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
xr
REV. 1.2.1
The on-chip oscillator is designed to use an industry standard microprocessor crystal (parallel resonant, fundamental frequency with 10-22 pF capacitance load, ESR of 20-120 ohms and 100ppm frequency tolerance) connected externally between the XTAL1 and XTAL2 pins (see Figure 4). The programmable Baud Rate Generator is capable of operating with a crystal oscillator frequency of up to 24 MHz. However, with an external clock input on XTAL1 pin and a 2K ohms pull-up resistor on XTAL2 pin (as shown in Figure 5) it can extend its operation up to 50 MHz (6.25 Mbps serial data rate) and 5V with an 8X sampling rate. FIGURE 5. EXTERNAL CLOCK CONNECTION FOR EXTENDED DATA RATE
vcc gnd
External Clock
XTAL1
VCC R1 2K XTAL2
For further reading on the oscillator circuit please see the Application Note DAN108 on the EXAR web site at http://www.exar.com. 2.11 Programmable Baud Rate Generator Each UART has its own Baud Rate Generator (BRG) with a prescaler. The prescaler is controlled by a software bit in the MCR register. The MCR register bit-7 sets the prescaler to divide the input crystal or external clock by 1 or 4. The clock output of the prescaler goes to the BRG. The BRG further divides this clock by a programmable divisor between 1 and (216 -1) to obtain a 16X sampling rate clock of the serial data rate. The sampling rate clock is used by the transmitter for data bit shifting and receiver for data sampling. The BRG divisor defaults to the maximum baud rate (DLL = 0x01 and DLM = 0x00) upon power up. FIGURE 6. BAUD RATE GENERATOR AND PRESCALER
DLL and DLM Registers Prescaler Divide by 1 XTAL1 XTAL2 Crystal Osc/ Buffer Prescaler Divide by 4 MCR Bit-7=0 (default) Baud Rate Generator Logic MCR Bit-7=1 16X Sampling Rate Clock to Transmitter
Programming the Baud Rate Generator Registers DLM and DLL provides the capability of selecting the operating data rate. Table 5 shows the standard data rates available with a 14.7456 MHz crystal or external clock at 16X sampling rate clock rate. A 16X sampling clock is typically used. However, user can select the 8X sampling clock rate mode (EMSR bit-7=0) to double the operating data rate. When using a non-standard data rate crystal or external clock, the divisor value can be calculated for DLL/DLM with the following equation.
10
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
divisor (decimal) = (XTAL1 clock frequency / prescaler) / (serial data rate x 16), with 16XMode [EMSR bit-7] = 1 divisor (decimal) = (XTAL1 clock frequency / prescaler) / (serial data rate x 8), with 16XMode [EMSR bit-7] = 0
TABLE 5: TYPICAL DATA RATES WITH A 14.7456 MHZ CRYSTAL OR EXTERNAL CLOCK
OUTPUT Data Rate OUTPUT Data Rate DIVISOR FOR 16x DIVISOR FOR 16x MCR Bit-7=1 MCR Bit-7=0 Clock (Decimal) Clock (HEX) (DEFAULT) 100 600 1200 2400 4800 9600 19.2k 38.4k 57.6k 115.2k 230.4k 400 2400 4800 9600 19.2k 38.4k 76.8k 153.6k 230.4k 460.8k 921.6k 2304 384 192 96 48 24 12 6 4 2 1 900 180 C0 60 30 18 0C 06 04 02 01 DLM PROGRAM VALUE (HEX) 09 01 00 00 00 00 00 00 00 00 00 DLL PROGRAM VALUE (HEX) 00 80 C0 60 30 18 0C 06 04 02 01 DATA RATE ERROR (%) 0 0 0 0 0 0 0 0 0 0 0
2.12
Transmitter
The transmitter section comprises of an 8-bit Transmit Shift Register (TSR) and 64 bytes of FIFO which includes a byte-wide Transmit Holding Register (THR). TSR shifts out every data bit with the 16X internal clock. A bit time is 16 clock periods (see EMSR bit-7). The transmitter sends the start-bit followed by the number of data bits, inserts the proper parity-bit if enabled, and adds the stop-bit(s). The status of the FIFO and TSR are reported in the Line Status Register (LSR bit-5 and bit-6). 2.12.1 Transmit Holding Register (THR) - Write Only The transmit holding register is an 8-bit register providing a data interface to the host processor. The host writes transmit data byte to the THR to be converted into a serial data stream including start-bit, data bits, parity-bit and stop-bit(s). The least-significant-bit (Bit-0) becomes first data bit to go out. The THR is the input register to the transmit FIFO of 64 bytes when FIFO operation is enabled by FCR bit-0. Every time a write operation is made to the THR, the FIFO data pointer is automatically bumped to the next sequential data location. 2.12.2 Transmitter Operation in non-FIFO Mode The host loads transmit data to THR one character at a time. The THR empty flag (LSR bit-5) is set when the data byte is transferred to TSR. THR flag can generate a transmit empty interrupt (ISR bit-1) when it is enabled by IER bit-1. The TSR flag (LSR bit-6) is set when TSR becomes completely empty.
11
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO FIGURE 7. TRANSMITTER OPERATION IN NON-FIFO MODE
xr
REV. 1.2.1
Data Byte
Transmit Holding Register (THR)
THR Interrupt (ISR bit-1) Enabled by IER bit-1
16X or 8X Clock (EMSR bit-7) Transmit Shift Register (TSR)
M S B
L S B
TXNOFIFO1
2.12.3
Transmitter Operation in FIFO Mode
The host may fill the transmit FIFO with up to 64 bytes of transmit data. The THR empty flag (LSR bit-5) is set whenever the FIFO is empty. The THR empty flag can generate a transmit empty interrupt (ISR bit-1) when the amount of data in the FIFO falls below its programmed trigger level. The transmit empty interrupt is enabled by IER bit-1. The TSR flag (LSR bit-6) is set when TSR/FIFO becomes empty. FIGURE 8. TRANSMITTER OPERATION IN FIFO AND FLOW CONTROL MODE
Transmit Data Byte
Transm it FIFO
THR Interrupt (ISR bit-1) falls below the programmed Trigger Level and then when becomes empty. FIFO is Enabled by FCR bit-0=1
Auto CTS Flow Control (CTS# pin) Flow Control Characters (Xoff1/2 and Xon1/2 Reg. Auto Software Flow Control
16X or 8X Clock (EMSR bit-7 = 1)
Transm it Data Shift Register (TSR)
T XF IF O 1
2.13
Receiver
The receiver section contains an 8-bit Receive Shift Register (RSR) and 64 bytes of FIFO which includes a byte-wide Receive Holding Register (RHR). The RSR uses the 16X for timing. It verifies and validates every bit on the incoming character in the middle of each data bit. On the falling edge of a start or false start bit, an internal receiver counter starts counting at the 16X. After 8 clocks the start bit period should be at the center of the start bit. At this time the start bit is sampled and if it is still a logic 0 it is validated. Evaluating the start bit in this manner prevents the receiver from assembling a false character. The rest of the data bits and stop bits are sampled and validated in this same manner to prevent false framing. If there were any error(s), they are reported in the LSR register bits 2-4. Upon unloading the receive data byte from RHR, the receive FIFO pointer is bumped and the error tags are immediately updated to reflect the status of the data byte in RHR register. RHR can generate a receive data ready interrupt upon receiving a character or delay until it reaches the FIFO trigger level. Furthermore, data delivery to the host is guaranteed by a receive data ready time-out interrupt
12
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
when data is not received for 4 word lengths as defined by LCR[1,0] plus 12 bits time. This is equivalent to 3.74.6 character times. The RHR interrupt is enabled by IER bit-0. 2.13.1 Receive Holding Register (RHR) - Read-Only The Receive Holding Register is an 8-bit register that holds a receive data byte from the Receive Shift Register. It provides the receive data interface to the host processor. The RHR register is part of the receive FIFO of 64 bytes by 11-bits wide, the 3 extra bits are for the 3 error tags to be reported in LSR register. When the FIFO is enabled by FCR bit-0, the RHR contains the first data character received by the FIFO. After the RHR is read, the next character byte is loaded into the RHR and the errors associated with the current data byte are immediately updated in the LSR bits 2-4. FIGURE 9. RECEIVER OPERATION IN NON-FIFO MODE
16X or 8X Clock (EMSR bit-7)
Receive Data Shift Register (RSR)
Data Bit Validation
Receive Data Characters
Receive Data Byte and Errors
Error Tags in LSR bits 4:2
Receive Data Holding Register (RHR)
RHR Interrupt (ISR bit-2)
RXFIFO1
FIGURE 10. RECEIVER OPERATION IN FIFO AND AUTO RTS FLOW CONTROL MODE
16X or 8X Clock (EMSR bit-7)
Receive Data Shift Register (RSR)
Data Bit Validation
Receive Data Characters
64 bytes by 11-bit wide FIFO Error Tags (64-sets)
Data falls to 8 RTS# re-asserts when data falls below the flow
Example - :RX FIFO trigger level selected at 16 bytes (See Note Below)
Receive Data FIFO
control trigger level to restart remote transmitter. Enable by EFR bit-6=1, MCR bit-2. desired FIFO trigger level. FIFO is Enabled by FCR bit-0=1
FIFO Trigger=16 RHR Interrupt (ISR bit-2) programmed for
Data fills to 24 Error Tags in LSR bits 4:2
RTS# de-asserts when data fills above the flow control trigger level to suspend remote transmitter. Enable by EFR bit-6=1, MCR bit-2.
Receive Data Byte and Errors
Receive Data
RXFIFO1
NOTE: Table-B selected as Trigger Table for Figure 10 (Table 10).
13
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO 2.14 Auto RTS (Hardware) Flow Control
xr
REV. 1.2.1
Automatic RTS hardware flow control is used to prevent data overrun to the local receiver FIFO. The RTS# output is used to request remote unit to suspend/resume data transmission. The auto RTS flow control features is enabled to fit specific application requirement (see Figure 11):
* Enable auto RTS flow control using EFR bit-6. * The auto RTS function must be started by asserting RTS# output pin (MCR bit-1 to logic 1 after it is enabled).
If using the Auto RTS interrupt:
* Enable RTS interrupt through IER bit-6 (after setting EFR bit-4). The UART issues an interrupt when the
RTS# pin makes a transition from low to high: ISR bit-5 will be set to logic 1. 2.15 Auto RTS Hysteresis The 2752 has a new feature that provides flow control trigger hysteresis while maintaining compatibility with the XR16C850, ST16C650A and ST16C550 family of UARTs. With the Auto RTS function enabled, an interrupt is generated when the receive FIFO reaches the programmed RX trigger level. The RTS# pin will not be forced HIGH (RTS off), until the receive FIFO reaches the upper limit of the hysteresis level. The RTS# pin will return LOW after the RX FIFO is unloaded to the lower limit of the hysteresis level. Under the above described conditions, the 2752 will continue to accept data until the receive FIFO gets full. The Auto RTS function is initiated when the RTS# output pin is asserted LOW (RTS On). Table 13 shows the complete details for the Auto RTS# Hysteresis levels. Please note that this table is for programmable trigger levels only (Table D). The hysteresis values for Tables A-C are the next higher and next lower trigger levels in Tables A-C. 2.16 Auto CTS Flow Control Automatic CTS flow control is used to prevent data overrun to the remote receiver FIFO. The CTS# input is monitored to suspend/restart the local transmitter. The auto CTS flow control feature is selected to fit specific application requirement (see Figure 11):
* Enable auto CTS flow control using EFR bit-7.
If using the Auto CTS interrupt:
* Enable CTS interrupt through IER bit-7 (after setting EFR bit-4). The UART issues an interrupt when the
CTS# pin is de-asserted (HIGH): ISR bit-5 will be set to 1, and UART will suspend transmission as soon as the stop bit of the character in process is shifted out. Transmission is resumed after the CTS# input is reasserted (LOW), indicating more data may be sent.
14
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
FIGURE 11. AUTO RTS AND CTS FLOW CONTROL OPERATION
Local UART UARTA Receiver FIFO Trigger Reached Auto RTS Trigger Level Transmitter Auto CTS Monitor RXA TXB Remote UART UARTB Transmitter Auto CTS Monitor Receiver FIFO Trigger Reached Auto RTS Trigger Level
RTSA# TXA
CTSB# RXB
CTSA# Assert RTS# to Begin Transmission 1 ON 2 7 ON 3 8 OFF
RTSB#
RTSA# CTSB# TXB
OFF
10 11
ON ON
Data Starts 4 RXA FIFO INTA (RXA FIFO Interrupt) Receive RX FIFO Data Trigger Level 5
6
Suspend
Restart 9
RTS High Threshold
RTS Low Threshold
12
RX FIFO Trigger Level
RTSCTS1
The local UART (UARTA) starts data transfer by asserting RTSA# (1). RTSA# is normally connected to CTSB# (2) of remote UART (UARTB). CTSB# allows its transmitter to send data (3). TXB data arrives and fills UARTA receive FIFO (4). When RXA data fills up to its receive FIFO trigger level, UARTA activates its RXA data ready interrupt (5) and continues to receive and put data into its FIFO. If interrupt service latency is long and data is not being unloaded, UARTA monitors its receive data fill level to match the upper threshold of RTS delay and de-assert RTSA# (6). CTSB# follows (7) and request UARTB transmitter to suspend data transfer. UARTB stops or finishes sending the data bits in its transmit shift register (8). When receive FIFO data in UARTA is unloaded to match the lower threshold of RTS delay (9), UARTA re-asserts RTSA# (10), CTSB# recognizes the change (11) and restarts its transmitter and data flow again until next receive FIFO trigger (12). This same event applies to the reverse direction when UARTA sends data to UARTB with RTSB# and CTSA# controlling the data flow.
15
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO 2.17 Auto Xon/Xoff (Software) Flow Control
xr
REV. 1.2.1
When software flow control is enabled (See Table 15), the 2752 compares one or two sequential receive data characters with the programmed Xon or Xoff-1,2 character value(s). If receive character(s) (RX) match the programmed values, the 2752 will halt transmission (TX) as soon as the current character has completed transmission. When a match occurs, the Xoff (if enabled via IER bit-5) flag will be set and the interrupt output pin will be activated. Following a suspension due to a match of the Xoff character, the 2752 will monitor the receive data stream for a match to the Xon-1,2 character. If a match is found, the 2752 will resume operation and clear the flags (ISR bit-4). Reset initially sets the contents of the Xon/Xoff 8-bit flow control registers to a logic 0. Following reset the user can write any Xon/Xoff value desired for software flow control. Different conditions can be set to detect Xon/ Xoff characters (See Table 15) and suspend/resume transmissions. When double 8-bit Xon/Xoff characters are selected, the 2752 compares two consecutive receive characters with two software flow control 8-bit values (Xon1, Xon2, Xoff1, Xoff2) and controls TX transmissions accordingly. Under the above described flow control mechanisms, flow control characters are not placed (stacked) in the user accessible RX data buffer or FIFO. In the event that the receive buffer is overfilling and flow control needs to be executed, the 2752 automatically sends an Xoff message (when enabled) via the serial TX output to the remote modem. The 2752 sends the Xoff-1,2 characters two-character-times (= time taken to send two characters at the programmed baud rate) after the receive FIFO crosses the programmed trigger level (for all trigger tables A-D). To clear this condition, the 2752 will transmit the programmed Xon-1,2 characters as soon as receive FIFO is less than one trigger level below the programmed trigger level (for Trigger Tables A, B, and C) or when receive FIFO is less than the trigger level minus the hysteresis value (for Trigger Table D). This hysteresis value is the same as the Auto RTS Hysteresis value in Table 13. Table 6 below explains this when Trigger Table-B (See Table 10) is selected. TABLE 6: AUTO XON/XOFF (SOFTWARE) FLOW CONTROL
RX TRIGGER LEVEL 8 16 24 28 INT PIN ACTIVATION 8 16 24 28 XOFF CHARACTER(S) SENT (CHARACTERS IN RX FIFO) 8* 16* 24* 28* XON CHARACTER(S) SENT (CHARACTERS IN RX FIFO) 0 8 16 24
* After the trigger level is reached, an xoff character is sent after a short span of time (= time required to send 2 characters); for example, after 2.083ms has elapsed for 9600 baud and 10-bit word length setting.
2.18
Special Character Detect
A special character detect feature is provided to detect an 8-bit character when bit-5 is set in the Enhanced Feature Register (EFR). When this character (Xoff2) is detected, it will be placed in the FIFO along with normal incoming RX data. The 2752 compares each incoming receive character with Xoff-2 data. If a match exists, the received data will be transferred to FIFO and ISR bit-4 will be set to indicate detection of special character. Although the Internal Register Table shows Xon, Xoff Registers with eight bits of character information, the actual number of bits is dependent on the programmed word length. Line Control Register (LCR) bits 0-1 defines the number of character bits, i.e., either 5 bits, 6 bits, 7 bits, or 8 bits. The word length selected by LCR bits 0-1 also determines the number of bits that will be used for the special character comparison. Bit-0 in the Xon, Xoff Registers corresponds with the LSB bit for the receive character. 2.19 Auto RS485 Half-duplex Control The auto RS485 half-duplex direction control changes the behavior of the transmitter when enabled by FCTR bit-3. By default, it de-asserts RTS# (HIGH) output following the last stop bit of the last character that has been transmitted. This helps in turning around the transceiver to receive the remote station's response. When the host is ready to transmit next polling data packet again, it only has to load data bytes to the transmit FIFO. The transmitter automatically re-asserts RTS# (LOW) output prior to sending the data. The RS485 half-duplex direction control output can be inverted by enabling EMSR bit-3.
16
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
2.20
Infrared Mode
The 2752 UART includes the infrared encoder and decoder compatible to the IrDA (Infrared Data Association) version 1.0. The IrDA 1.0 standard that stipulates the infrared encoder sends out a 3/16 of a bit wide HIGHpulse for each "0" bit in the transmit data stream. This signal encoding reduces the on-time of the infrared LED, hence reduces the power consumption. See Figure 12 below. The infrared encoder and decoder are enabled by setting MCR register bit-6 to a `1'. When the infrared feature is enabled, the transmit data output, TX, idles at logic zero level. Likewise, the RX input assumes an idle level of logic zero from a reset and power up, see Figure 12. Typically, the wireless infrared decoder receives the input pulse from the infrared sensing diode on the RX pin. Each time it senses a light pulse, it returns a logic 1 to the data bit stream. However, this is not true with some infrared modules on the market which indicate a logic 0 by a light pulse. So the 2752 has a provision to invert the input polarity to accommodate this. In this case user can enable FCTR bit-2 to invert the input signal. FIGURE 12. INFRARED TRANSMIT DATA ENCODING AND RECEIVE DATA DECODING
Character Start Stop 1 1 0 1 1/2 Bit Time 3/16 Bit Time
IrEncoder-1
Data Bits 1 0 1 0 0
TX Data
0
Transmit IR Pulse (TX Pin) Bit Time
Receive IR Pulse (RX pin)
Bit Time 1/16 Clock Delay
RX Data
0 Start
1
0
1
0
0
11
0
1 Stop
IRdecoder-
Data Bits Character
17
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO 2.21 Sleep Mode with Auto Wake-Up
xr
REV. 1.2.1
The 2752 supports low voltage system designs, hence, a sleep mode is included to reduce its power consumption when the chip is not actively used. All of these conditions must be satisfied for the 2752 to enter sleep mode: no interrupts pending for both channels of the 2752 (ISR bit-0 = 1) sleep mode of both channels are enabled (IER bit-4 = 1) modem inputs are not toggling (MSR bits 0-3 = 0) RX input pins are idling HIGH The 2752 stops its crystal oscillator to conserve power in the sleep mode. User can check the XTAL2 pin for no clock output as an indication that the device has entered the sleep mode. The 2752 resumes normal operation by any of the following: a receive data start bit transition (HIGH to LOW) a data byte is loaded to the transmitter, THR or FIFO a change of logic state on any of the modem or general purpose serial inputs: CTS#, DSR#, CD#, RI# If the 2752 is awakened by any one of the above conditions, it will return to the sleep mode automatically after all interrupting conditions have been serviced and cleared. If the 2752 is awakened by the modem inputs, a read to the MSR is required to reset the modem inputs. In any case, the sleep mode will not be entered while an interrupt is pending from channel A or B. The 2752 will stay in the sleep mode of operation until it is disabled by setting IER bit-4 to a logic 0. If the address lines, data bus lines, IOW#, IOR#, CSA#, CSB#, and modem input lines remain steady when the 2752 is in sleep mode, the maximum current will be in the microamp range as specified in the DC Electrical Characteristics on page 39. If the input lines are floating or are toggling while the 2752 is in sleep mode, the current can be up to 100 times more. If any of those signals are toggling or floating, then an external buffer would be required to keep the address, data and control lines steady to achieve the low current. As an alternative, please refer to the XR16L2751 with the PowerSave feature that eliminates any unnecessary external buffer. A word of caution: owing to the starting up delay of the crystal oscillator after waking up from sleep mode, the first few receive characters may be lost. The number of characters lost during the restart also depends on your operating data rate. More characters are lost when operating at higher data rate. Also, it is important to keep RX A/B inputs idling HIGH or "marking" condition during sleep mode to avoid receiving a "break" condition upon the restart. This may occur when the external interface transceivers (RS-232, RS-485 or another type) are also put to sleep mode and cannot maintain the "marking" condition. To avoid this, the designer can use a 47k-100k ohm pull-up resistor on the RXA and RXB pins.
18
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
2.22
Internal Loopback
The 2752 UART provides an internal loopback capability for system diagnostic purposes. The internal loopback mode is enabled by setting MCR register bit-4 to logic 1. All regular UART functions operate normally. Figure 13 shows how the modem port signals are re-configured. Transmit data from the transmit shift register output is internally routed to the receive shift register input allowing the system to receive the same data that it was sending. The TX pin is held HIGH or mark condition while RTS# and DTR# are de-asserted, and CTS#, DSR# CD# and RI# inputs are ignored. Caution: the RX input must be held HIGH during loopback test else upon exiting the loopback test the UART may detect and report a false "break" signal. Also, Auto RTS/CTS hardware flow control is not supported during internal loopback. FIGURE 13. INTERNAL LOOP BACK IN CHANNEL A AND B
VCC Transmit Shift Register (THR/FIFO) MCR bit-4=1 Internal Data Bus Lines and Control Signals Receive Shift Register (RHR/FIFO) VCC RTS# Modem / General Purpose Control Logic RTSA#/RTSB# TXA/TXB
RXA/RXB
CTS# VCC DTR# DSR# OP1# RI# VCC OP2# CD#
CTSA#/CTSB# DTRA#/DTRB#
DSRA#/DSRB# RIA#/RIB# (OP2A#/OP2B#)
CDA#/CDB#
19
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO 3.0 UART INTERNAL REGISTERS
xr
REV. 1.2.1
Each of the UART channel in the 2752 has its own set of configuration registers selected by address lines A0, A1 and A2 with CS# and CHSEL selecting the channel. The complete register set is shown in Table 7 and Table 8. TABLE 7: UART CHANNEL A AND B UART INTERNAL REGISTERS
ADDRESSES A2 A1 A0 REGISTER READ/WRITE COMMENTS
16C550 COMPATIBLE REGISTERS 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 00 00 01 10 00 01 01 10 11 00 01 10 11 11 11 RHR - Receive Holding Register THR - Transmit Holding Register DLL - Div Latch Low Byte DLM - Div Latch High Byte AFR - Alternate Function Register DREV - Device Revision Code DVID - Device Identification Code IER - Interrupt Enable Register ISR - Interrupt Status Register FCR - FIFO Control Register LCR - Line Control Register MCR - Modem Control Register LSR - Line Status Register Reserved MSR - Modem Status Register Reserved SPR - Scratch Pad Register FLVL - RX/TX FIFO Level Counter Register EMSR - Enhanced Mode Select Register ENHANCED REGISTERS 0 0 0 1 1 1 1 00 01 10 00 01 10 11 TRG -RX/TX FIFO Trigger Level Register FC - RX/TX FIFO Level Counter Register FCTR - Feature Control Register EFR - Enhanced Function Register Xon-1 - Xon Character 1 Xon-2 - Xon Character 2 Xoff-1 - Xoff Character 1 Xoff-2 - Xoff Character 2 Write-only Read-only Read/Write Read/Write Read/Write Read/Write Read/Write Read/Write LCR = 0xBF Read-only Write-only Read/Write Read/Write Read/Write Read-only Read-only Read/Write Read-only Write-only Read/Write Read/Write Read-only Write-only Read-only Write-only Read/Write Read-only Write-only LCR 0xBF, FCTR[6] = 0 LCR 0xBF, FCTR[6] = 1 LCR 0xBF DLL, DLM = 0x00, LCR[7] = 1, LCR 0xBF LCR[7] = 0 LCR[7] = 0 LCR[7] = 1, LCR 0xBF LCR[7] = 0
20
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
.
TABLE 8: INTERNAL REGISTERS DESCRIPTION. SHADED BITS ARE ENABLED WHEN EFR BIT-4=1
ADDRESS A2-A0 REG NAME READ/ WRITE BIT-7 BIT-6 BIT-5 BIT-4 BIT-3 BIT-2 BIT-1 BIT-0 COMMENT
16C550 Compatible Registers 000 000 001 RHR THR IER RD WR RD/WR Bit-7 Bit-7 0/ Bit-6 Bit-6 0/ Bit-5 Bit-5 0/ Xoff Int. Enable Bit-4 Bit-4 0/ Sleep Mode Enable 0/ INT Source Bit-4 0/ Bit-3 Bit-3 Bit-2 Bit-2 Bit-1 Bit-1 Bit-0 Bit-0
CTS Int. RTS Int. Enable Enable
Modem RX Line TX RX Stat. Stat. Empty Data Int. Int. Int Int. Enable Enable Enable Enable
010
ISR
RD
FIFOs FIFOs Enabled Enabled
0/ INT Source Bit-5 0/
INT INT INT INT Source Source Source Source Bit-3 Bit-2 Bit-1 Bit-0
LCR[7] = 0
010
FCR
WR
RX FIFO RX FIFO Trigger Trigger
DMA Mode TX FIFO TX FIFO Enable Trigger Trigger Set Parity 0/ Even Parity Parity Enable
TX FIFO Reset
RX FIFO Reset
FIFOs Enable
011
LCR
RD/WR
Divisor Enable 0/ BRG Prescaler
Set TX Break 0/
Stop Bits
Word Word Length Length Bit-1 Bit-0
100
MCR
RD/WR
Internal OP2# Rsrvd RTS# DTR# Lopback Output (OP1#) Output Output IR Mode XonAny Enable Control Control Control ENable
101
LSR
RD
RX FIFO Global Error CD# Input Bit-7 16X Sampling Rate Mode Bit-7
THR & TSR Empty RI# Input Bit-6 LSR Error Interrupt. Imd/Dly#
THR Empty
RX Break
RX Framing Error Delta CD# Bit-3 Auto RS485 Output Inversion
RX Parity Error Delta RI# Bit-2 Rsrvd
RX Overrun Error Delta DSR# Bit-1 Rx/Tx FIFO Count
RX Data Ready Delta CTS# Bit-0 Rx/Tx FIFO Count
LCR 0xBF
110 111 111
MSR SPR EMSR
RD RD/WR WR
DSR# Input Bit-5 Auto RTS Hyst. bit-3
CTS# Input Bit-4 Auto RTS Hyst. bit-2
LCR 0xBF FCTR bit-6=0
LCR 0xBF FCTR bit-6=1
111
FLVL
RD
Bit-6
Bit-5
Bit-4
Bit-3
Bit-2
Bit-1
Bit-0
21
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
xr
REV. 1.2.1
TABLE 8: INTERNAL REGISTERS DESCRIPTION. SHADED BITS ARE ENABLED WHEN EFR BIT-4=1
ADDRESS A2-A0 REG NAME READ/ WRITE BIT-7 BIT-6 BIT-5 BIT-4 BIT-3 BIT-2 BIT-1 BIT-0 COMMENT
Baud Rate Generator Divisor 000 001 010 000 001 DLL DLM AFR DREV DVID RD/WR RD/WR RD/WR RD RD Bit-7 Bit-7 Rsvd Bit-7 0 Bit-6 Bit-6 Rsvd Bit-6 0 Bit-5 Bit-5 Rsvd Bit-5 0 Bit-4 Bit-4 Rsvd Bit-4 0 Bit-3 Bit-3 Rsvd Bit-3 1 Bit-2 Bit-2 Bit-1 Bit-1 Bit-0 Bit-0 LCR[7] = 1 LCR 0xBF
RXRDY# Baudout# Concurrent Write Select Select
Bit-2 0
Bit-1 1
Bit-0 0
LCR[7] = 1 LCR 0xBF DLL=0x00 DLM=0x00
Enhanced Registers 000 000 001 TRG FC WR RD Bit-7 Bit-7 RX/TX Mode Bit-6 Bit-6 SCPAD Swap Bit-5 Bit-5 Trig Table Bit-1 Bit-4 Bit-4 Trig Table Bit-0 Bit-3 Bit-3 Auto RS485 Direction Control Software Flow Cntl Bit-3 Bit-3 Bit-3 Bit-3 Bit-3 Bit-2 Bit-2 RX IR Input Inv. Bit-1 Bit-1 Auto RTS Hyst Bit-1 Software Flow Cntl Bit-1 Bit-1 Bit-1 Bit-1 Bit-1 Bit-0 Bit-0 Auto RTS Hyst Bit-0 Software Flow Cntl Bit-0 Bit-0 Bit-0 Bit-0 Bit-0
FCTR RD/WR
010
EFR
RD/WR
Auto CTS Enable
Auto RTS Enable
Special Char Select
Enable IER [7:4], ISR [5:4], FCR[5:4], MCR[7:5]
Software Flow Cntl Bit-2 Bit-2 Bit-2 Bit-2 Bit-2
LCR=0XBF
100 101 110 111
XON1 RD/WR XON2 RD/WR XOFF1 RD/WR XOFF2 RD/WR
Bit-7 Bit-7 Bit-7 Bit-7
Bit-6 Bit-6 Bit-6 Bit-6
Bit-5 Bit-5 Bit-5 Bit-5
Bit-4 Bit-4 Bit-4 Bit-4
4.0 INTERNAL REGISTER DESCRIPTIONS 4.1 4.2 4.3 Receive Holding Register (RHR) - Read- Only Transmit Holding Register (THR) - Write-Only Interrupt Enable Register (IER) - Read/Write See "Receiver" on page 12. See "Transmitter" on page 11. The Interrupt Enable Register (IER) masks the interrupts from receive data ready, transmit empty, line status and modem status registers. These interrupts are reported in the Interrupt Status Register (ISR).
22
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
4.3.1
IER versus Receive FIFO Interrupt Mode Operation
When the receive FIFO (FCR BIT-0 = 1) and receive interrupts (IER BIT-0 = 1) are enabled, the RHR interrupts (see ISR bits 2 and 3) status will reflect the following: A. The receive data available interrupts are issued to the host when the FIFO has reached the programmed trigger level. It will be cleared when the FIFO drops below the programmed trigger level. B. FIFO level will be reflected in the ISR register when the FIFO trigger level is reached. Both the ISR register status bit and the interrupt will be cleared when the FIFO drops below the trigger level. C. The receive data ready bit (LSR BIT-0) is set as soon as a character is transferred from the shift register to the receive FIFO. It is reset when the FIFO is empty. 4.3.2 IER versus Receive/Transmit FIFO Polled Mode Operation When FCR BIT-0 equals a logic 1 for FIFO enable; resetting IER bits 0-3 enables the XR16L2752 in the FIFO polled mode of operation. Since the receiver and transmitter have separate bits in the LSR either or both can be used in the polled mode by selecting respective transmit or receive control bit(s). A. LSR BIT-0 indicates there is data in RHR or RX FIFO. B. LSR BIT-1 indicates an overrun error has occurred and that data in the FIFO may not be valid. C. LSR BIT 2-4 provides the type of receive data errors encountered for the data byte in RHR, if any. D. LSR BIT-5 indicates THR is empty. E. LSR BIT-6 indicates when both the transmit FIFO and TSR are empty. F. LSR BIT-7 indicates a data error in at least one character in the RX FIFO. IER[0]: RHR Interrupt Enable The receive data ready interrupt will be issued when RHR has a data character in the non-FIFO mode or when the receive FIFO has reached the programmed trigger level in the FIFO mode.
* Logic 0 = Disable the receive data ready interrupt (default). * Logic 1 = Enable the receiver data ready interrupt.
IER[1]: THR Interrupt Enable This bit enables the Transmit Ready interrupt which is issued whenever the THR becomes empty in the nonFIFO mode or when data in the FIFO falls below the programmed trigger level in the FIFO mode. If the THR is empty when this bit is enabled, an interrupt will be generated.
* Logic 0 = Disable Transmit Ready interrupt (default). * Logic 1 = Enable Transmit Ready interrupt.
IER[2]: Receive Line Status Interrupt Enable If any of the LSR register bits 1, 2, 3 or 4 is a logic 1, it will generate an interrupt to inform the host controller about the error status of the current data byte in FIFO. LSR bits 1-4 generate an interrupt immediately when the character has been received.
* Logic 0 = Disable the receiver line status interrupt (default). * Logic 1 = Enable the receiver line status interrupt.
IER[3]: Modem Status Interrupt Enable
* Logic 0 = Disable the modem status register interrupt (default). * Logic 1 = Enable the modem status register interrupt.
IER[4]: Sleep Mode Enable (requires EFR bit-4 = 1)
* Logic 0 = Disable Sleep Mode (default). * Logic 1 = Enable Sleep Mode. See Sleep Mode section for further details.
23
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO IER[5]: Xoff Interrupt Enable (requires EFR bit-4=1)
xr
REV. 1.2.1
* Logic 0 = Disable the software flow control, receive Xoff interrupt. (default) * Logic 1 = Enable the software flow control, receive Xoff interrupt. See Software Flow Control section for
details. IER[6]: RTS# Output Interrupt Enable (requires EFR bit-4=1)
* Logic 0 = Disable the RTS# interrupt (default). * Logic 1 = Enable the RTS# interrupt. The UART issues an interrupt when the RTS# pin makes a transition
from low to high. IER[7]: CTS# Input Interrupt Enable (requires EFR bit-4=1)
* Logic 0 = Disable the CTS# interrupt (default). * Logic 1 = Enable the CTS# interrupt. The UART issues an interrupt when CTS# pin makes a transition from
low to high. 4.4 Interrupt Status Register (ISR) - Read-Only The UART provides multiple levels of prioritized interrupts to minimize external software interaction. The Interrupt Status Register (ISR) provides the user with six interrupt status bits. Performing a read cycle on the ISR will give the user the current highest pending interrupt level to be serviced, others are queued up to be serviced next. No other interrupts are acknowledged until the pending interrupt is serviced. The Interrupt Source Table, Table 9, shows the data values (bit 0-5) for the interrupt priority levels and the interrupt sources associated with each of these interrupt levels. 4.4.1 Interrupt Generation:
* LSR is by any of the LSR bits 1, 2, 3 and 4. * RXRDY is by RX trigger level. * RXRDY Time-out is by a 4-char plus 12 bits delay timer. * TXRDY is by TX trigger level or TX FIFO empty (or transmitter empty in auto RS-485 control). * MSR is by any of the MSR bits 0, 1, 2 and 3. * Receive Xoff/Special character is by detection of a Xoff or Special character. * CTS# is when its transmitter toggles the input pin (from LOW to HIGH) during auto CTS flow control. * RTS# is when its receiver toggles the output pin (from LOW to HIGH) during auto RTS flow control.
4.4.2 Interrupt Clearing:
* LSR interrupt is cleared by a read to the LSR register. * RXRDY interrupt is cleared by reading data until FIFO falls below the trigger level. * RXRDY Time-out interrupt is cleared by reading RHR. * TXRDY interrupt is cleared by a read to the ISR register or writing to THR. * MSR interrupt is cleared by a read to the MSR register. * Xoff interrupt is cleared by a read to ISR or when Xon character(s) is received. * Special character interrupt is cleared by a read to ISR or after the next character is received. * RTS# and CTS# flow control interrupts are cleared by a read to the MSR register.
24
xr
REV. 1.2.1
]
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO TABLE 9: INTERRUPT SOURCE AND PRIORITY LEVEL
PRIORITY LEVEL 1 2 3 4 5 6 7 BIT-5 0 0 0 0 0 0 1 0
ISR REGISTER STATUS BITS BIT-4 0 0 0 0 0 1 0 0 BIT-3 0 1 0 0 0 0 0 0 BIT-2 1 1 1 0 0 0 0 0 BIT-1 1 0 0 1 0 0 0 0 BIT-0 0 0 0 0 0 0 0 1
SOURCE OF INTERRUPT
LSR (Receiver Line Status Register) RXRDY (Receive Data Time-out) RXRDY (Received Data Ready) TXRDY (Transmit Ready) MSR (Modem Status Register) RXRDY (Received Xoff or Special character) CTS#, RTS# change of state None (default)
ISR[0]: Interrupt Status
* Logic 0 = An interrupt is pending and the ISR contents may be used as a pointer to the appropriate interrupt
service routine.
* Logic 1 = No interrupt pending (default condition).
ISR[3:1]: Interrupt Status These bits indicate the source for a pending interrupt at interrupt priority levels (See Interrupt Source Table 9). ISR[5:4]: Interrupt Status These bits are enabled when EFR bit-4 is set to a logic 1. ISR bit-4 indicates that the receiver detected a data match of the Xoff character(s). Note that once set to a logic 1, the ISR bit-4 will stay a logic 1 until a Xon character is received. ISR bit-5 indicates that CTS# or RTS# has changed state. ISR[7:6]: FIFO Enable Status These bits are set to a logic 0 when the FIFOs are disabled. They are set to a logic 1 when the FIFOs are enabled. 4.5 FIFO Control Register (FCR) - Write-Only This register is used to enable the FIFOs, clear the FIFOs, set the transmit/receive FIFO trigger levels, and select the DMA mode. The DMA, and FIFO modes are defined as follows: FCR[0]: TX and RX FIFO Enable
* Logic 0 = Disable the transmit and receive FIFO (default). * Logic 1 = Enable the transmit and receive FIFOs. This bit must be set to logic 1 when other FCR bits are
written or they will not be programmed. FCR[1]: RX FIFO Reset This bit is only active when FCR bit-0 is a `1'.
* Logic 0 = No receive FIFO reset (default) * Logic 1 = Reset the receive FIFO pointers and FIFO level counter logic (the receive shift register is not
cleared or altered). This bit will return to a logic 0 after resetting the FIFO.
25
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO FCR[2]: TX FIFO Reset This bit is only active when FCR bit-0 is a `1'.
xr
REV. 1.2.1
* Logic 0 = No transmit FIFO reset (default). * Logic 1 = Reset the transmit FIFO pointers and FIFO level counter logic (the transmit shift register is not
cleared or altered). This bit will return to a logic 0 after resetting the FIFO. FCR[3]: DMA Mode Select Controls the behavior of the TXRDY# and RXRDY# pins. See DMA operation section for details.
* Logic 0 = Normal Operation (default). * Logic 1 = DMA Mode.
FCR[5:4]: Transmit FIFO Trigger Select (logic 0 = default, TX trigger level = one) These 2 bits set the trigger level for the transmit FIFO. The UART will issue a transmit interrupt when the number of characters in the FIFO falls below the selected trigger level, or when it gets empty in case that the FIFO did not get filled over the trigger level on last re-load. Table 10 below shows the selections. EFR bit-4 must be set to `1' before these bits can be accessed. Note that the receiver and the transmitter cannot use different trigger tables. Whichever selection is made last applies to both the RX and TX side. FCR[7:6]: Receive FIFO Trigger Select (logic 0 = default, RX trigger level =1) The FCTR Bits 5-4 are associated with these 2 bits. These 2 bits are used to set the trigger level for the receive FIFO. The UART will issue a receive interrupt when the number of the characters in the FIFO crosses the trigger level. Table 10 shows the complete selections. Note that the receiver and the transmitter cannot use different trigger tables. Whichever selection is made last applies to both the RX and TX side.
26
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
TABLE 10: TRANSMIT AND RECEIVE FIFO TRIGGER TABLE AND LEVEL SELECTION
TRIGGER TABLE Table-A FCTR BIT-5 0 FCTR BIT-4 0 0 0 1 1 Table-B 0 1 0 1 0 1 0 0 1 1 0 0 1 1 Table-C 1 0 0 1 0 1 0 0 1 1 0 0 1 1 Table-D 1 1 X 0 1 0 1 X X X 0 1 0 1 8 16 56 60 Programmable Programmable 16L2752, 16C2850, 16C2852, 16C850, via TRG via TRG 16C854, 16C864 register. register. FCTR[7] = 0. FCTR[7] = 1. 0 1 0 1 8 16 24 28 8 16 32 56 16C654 FCR BIT-7 FCR BIT-6 FCR BIT-5 0 FCR
BIT-4
RECEIVE TRIGGER LEVEL
TRANSMIT TRIGGER LEVEL 1 (default)
COMPATIBILITY 16C550, 16C2550, 16C2552, 16C554, 16C580
0 1 (default) 4 8 14
16 8 24 30
16C650A
4.6
Line Control Register (LCR) - Read/Write
The Line Control Register is used to specify the asynchronous data communication format. The word or character length, the number of stop bits, and the parity are selected by writing the appropriate bits in this register. LCR[1:0]: TX and RX Word Length Select These two bits specify the word length to be transmitted or received.
BIT-1 0 0 1 1 BIT-0 0 1 0 1 WORD LENGTH 5 (default) 6 7 8
27
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO LCR[2]: TX and RX Stop-bit Length Select The length of stop bit is specified by this bit in conjunction with the programmed word length.
BIT-2 0 1 1 WORD
LENGTH
xr
REV. 1.2.1
STOP BIT LENGTH (BIT TIME(S)) 1 (default) 1-1/2 2
5,6,7,8 5 6,7,8
LCR[3]: TX and RX Parity Select Parity or no parity can be selected via this bit. The parity bit is a simple way used in communications for data integrity check. See Table 11 for parity selection summary below.
* Logic 0 = No parity. * Logic 1 = A parity bit is generated during the transmission while the receiver checks for parity error of the
data character received. LCR[4]: TX and RX Parity Select If the parity bit is enabled with LCR bit-3 set to a logic 1, LCR BIT-4 selects the even or odd parity format.
* Logic 0 = ODD Parity is generated by forcing an odd number of logic 1's in the transmitted character. The
receiver must be programmed to check the same format (default).
* Logic 1 = EVEN Parity is generated by forcing an even number of logic 1's in the transmitted character. The
receiver must be programmed to check the same format. LCR[5]: TX and RX Parity Select If the parity bit is enabled, LCR BIT-5 selects the forced parity format.
* LCR BIT-5 = logic 0, parity is not forced (default). * LCR BIT-5 = logic 1 and LCR BIT-4 = logic 0, parity bit is forced to a logical 1 for the transmit and receive
data.
* LCR BIT-5 = logic 1 and LCR BIT-4 = logic 1, parity bit is forced to a logical 0 for the transmit and receive
data. TABLE 11: PARITY SELECTION
LCR BIT-5 LCR BIT-4 LCR BIT-3 X 0 0 1 1 X 0 1 0 1 0 1 1 1 1 PARITY SELECTION No parity Odd parity Even parity Force parity to mark, "1" Forced parity to space, "0"
28
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
LCR[6]: Transmit Break Enable When enabled, the Break control bit causes a break condition to be transmitted (the TX output is forced to a "space", LOW state). This condition remains, until disabled by setting LCR bit-6 to a logic 0.
* Logic 0 = No TX break condition (default). * Logic 1 = Forces the transmitter output (TX) to a "space", LOW, for alerting the remote receiver of a line
break condition. LCR[7]: Baud Rate Divisors Enable Baud rate generator divisor (DLL/DLM) enable.
* Logic 0 = Data registers are selected (default). * Logic 1 = Divisor latch registers are selected.
4.7 Alternate Function Register (AFR) - Read/Write This register is used to select specific modes of MF# operation and to allow both UART register sets to be written concurrently. AFR[0]: Concurrent Write Mode When this bit is set, the CPU can write concurrently to the same register in both UARTs. This function is intended to reduce the dual UART initialization time. It can be used by the CPU when both channels are initialized to the same state. The external CPU can set or clear this bit by accessing either register set. When this bit is set, the channel select pin still selects the channel to be accessed during read operations. The user should ensure that LCR Bit-7 of both channels are in the same state before executing a concurrent write to the registers at address 0, 1, or 2.
* Logic 0 = No concurrent write (default). * Logic 1 = Register set A and B are written concurrently with a single external CPU I/O write operation.
AFR[2:1]: MF# Output Select These bits select a signal function for output on the MF# A/B pins. These signal function are described as: OP2#, BAUDOUT#, or RXRDY#. Only one signal function can be selected at a time.
BIT-2 0 0 1 1 BIT-1 0 1 0 1 MF# FUNCTION OP2# (default) BAUDOUT# RXRDY# Reserved
AFR[7:3]: Reserved All are initialized to logic 0. 4.8 Modem Control Register (MCR) or General Purpose Outputs Control - Read/Write The MCR register is used for controlling the serial/modem interface signals or general purpose inputs/outputs. MCR[0]: DTR# Output The DTR# pin is a modem control output. If the modem interface is not used, this output may be used as a general purpose output.
* Logic 0 = Force DTR# output HIGH (default). * Logic 1 = Force DTR# output LOW.
29
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO MCR[1]: RTS# Output
xr
REV. 1.2.1
The RTS# pin is a modem control output and may be used for automatic hardware flow control by enabled by EFR bit-6. If the modem interface is not used, this output may be used as a general purpose output.
* Logic 0 = Force RTS# output HIGH (default). * Logic 1 = Force RTS# output LOW.
MCR[2]: Reserved OP1# is not available as an output pin on the 2752. But it is available for use during Internal Loopback Mode. In the Loopback Mode, this bit is used to write the state of the modem RI# interface signal. MCR[3]: OP2# Output / INT Output Enable OP2# is available as an output pin on the 2752 when AFR[2:1] = `00'. In the Loopback Mode, MCR[3] is used to write the state of the modem CD# interface signal. Also see pin descriptions for MF# pins.
* Logic 0 = Forces OP2# output HIGH (default). * Logic 1 = Forces OP2# output LOW.
MCR[4]: Internal Loopback Enable
* Logic 0 = Disable loopback mode (default). * Logic 1 = Enable local loopback mode, see loopback section and Figure 13.
MCR[5]: Xon-Any Enable
* Logic 0 = Disable Xon-Any function (for 16C550 compatibility, default). * Logic 1 = Enable Xon-Any function. In this mode, any RX character received will resume transmit operation.
The RX character will be loaded into the RX FIFO, unless the RX character is an Xon or Xoff character and the 2752 is programmed to use the Xon/Xoff flow control. MCR[6]: Infrared Encoder/Decoder Enable
* Logic 0 = Enable the standard modem receive and transmit input/output interface (default). * Logic 1 = Enable infrared IrDA receive and transmit inputs/outputs. The TX/RX output/input are routed to the
infrared encoder/decoder. The data input and output levels conform to the IrDA infrared interface requirement. While in this mode, the infrared TX output will be a logic 0 during idle data conditions. MCR[7]: Clock Prescaler Select
* Logic 0 = Divide by one. The input clock from the crystal or external clock is fed directly to the Programmable
Baud Rate Generator without further modification, i.e., divide by one (default).
* Logic 1 = Divide by four. The prescaler divides the input clock from the crystal or external clock by four and
feeds it to the Programmable Baud Rate Generator, hence, data rates become one forth. 4.9 Line Status Register (LSR) - Read Only This register provides the status of data transfers between the UART and the host. LSR[0]: Receive Data Ready Indicator
* Logic 0 = No data in receive holding register or FIFO (default). * Logic 1 = Data has been received and is saved in the receive holding register or FIFO.
LSR[1]: Receiver Overrun Flag
* Logic 0 = No overrun error. (default) * Logic 1 = Overrun error. A data overrun error condition occurred in the receive shift register. This happens
when additional data arrives while the FIFO is full. In this case the previous data in the receive shift register is overwritten. Note that under this condition the data byte in the receive shift register is not transferred into the FIFO, therefore the data in the FIFO is not corrupted by the error.
30
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
LSR[2]: Receive Data Parity Error Flag
* Logic 0 = No parity error (default). * Logic 1 = Parity error. The receive character in RHR does not have correct parity information and is suspect.
This error is associated with the character available for reading in RHR. LSR[3]: Receive Data Framing Error Flag
* Logic 0 = No framing error (default). * Logic 1 = Framing error. The receive character did not have a valid stop bit(s). This error is associated with
the character available for reading in RHR. LSR[4]: Receive Break Flag
* Logic 0 = No break condition (default). * Logic 1 = The receiver received a break signal (RX was a logic 0 for at least one character frame time). In the
FIFO mode, only one break character is loaded into the FIFO. LSR[5]: Transmit Holding Register Empty Flag This bit is the Transmit Holding Register Empty indicator. The THR bit is set to a logic 1 when the last data byte is transferred from the transmit holding register to the transmit shift register. The bit is reset to logic 0 concurrently with the data loading to the transmit holding register by the host. In the FIFO mode this bit is set when the transmit FIFO is empty, it is cleared when the transmit FIFO contains at least 1 byte. LSR[6]: THR and TSR Empty Flag This bit is set to a logic 1 whenever the transmitter goes idle. It is set to logic 0 whenever either the THR or TSR contains a data character. In the FIFO mode this bit is set to a logic 1 whenever the transmit FIFO and transmit shift register are both empty. LSR[7]: Receive FIFO Data Error Flag
* Logic 0 = No FIFO error (default). * Logic 1 = A global indicator for the sum of all error bits in the RX FIFO. At least one parity error, framing error
or break indication is in the FIFO data. This bit clears when there is no more error(s) in any of the bytes in the RX FIFO. 4.10 Modem Status Register (MSR) - Read Only This register provides the current state of the modem interface input signals. Lower four bits of this register are used to indicate the changed information. These bits are set to a logic 1 whenever a signal from the modem changes state. These bits may be used as general purpose inputs when they are not used with modem signals. MSR[0]: Delta CTS# Input Flag
* Logic 0 = No change on CTS# input (default). * Logic 1 = The CTS# input has changed state since the last time it was monitored. A modem status interrupt
will be generated if MSR interrupt is enabled (IER bit-3). MSR[1]: Delta DSR# Input Flag
* Logic 0 = No change on DSR# input (default). * Logic 1 = The DSR# input has changed state since the last time it was monitored. A modem status interrupt
will be generated if MSR interrupt is enabled (IER bit-3). MSR[2]: Delta RI# Input Flag
* Logic 0 = No change on RI# input (default). * Logic 1 = The RI# input has changed from a LOW to HIGH, ending of the ringing signal. A modem status
interrupt will be generated if MSR interrupt is enabled (IER bit-3).
31
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO MSR[3]: Delta CD# Input Flag
xr
REV. 1.2.1
* Logic 0 = No change on CD# input (default). * Logic 1 = Indicates that the CD# input has changed state since the last time it was monitored. A modem
status interrupt will be generated if MSR interrupt is enabled (IER bit-3). MSR[4]: CTS Input Status CTS# pin may function as automatic hardware flow control signal input if it is enabled and selected by Auto CTS (EFR bit-7). Auto CTS flow control allows starting and stopping of local data transmissions based on the modem CTS# signal. A HIGH on the CTS# pin will stop UART transmitter as soon as the current character has finished transmission, and a LOW will resume data transmission. Normally MSR bit-4 bit is the complement of the CTS# input. However in the loopback mode, this bit is equivalent to the RTS# bit in the MCR register. The CTS# input may be used as a general purpose input when the modem interface is not used. MSR[5]: DSR Input Status Normally this bit is the complement of the DSR# input. In the loopback mode, this bit is equivalent to the DTR# bit in the MCR register. The DSR# input may be used as a general purpose input when the modem interface is not used. MSR[6]: RI Input Status Normally this bit is the complement of the RI# input. In the loopback mode this bit is equivalent to bit-2 in the MCR register. The RI# input may be used as a general purpose input when the modem interface is not used. MSR[7]: CD Input Status Normally this bit is the complement of the CD# input. In the loopback mode this bit is equivalent to bit-3 in the MCR register. The CD# input may be used as a general purpose input when the modem interface is not used. 4.11 Scratch Pad Register (SPR) - Read/Write This is a 8-bit general purpose register for the user to store temporary data. The content of this register is preserved during sleep mode but becomes 0xFF (default) after a reset or a power off-on cycle. 4.12 Enhanced Mode Select Register (EMSR) This register replaces SPR (during a Write) and is accessible only when FCTR[6] = 1. EMSR[1:0]: Receive/Transmit FIFO Count (Write-Only) When Scratchpad Swap (FCTR[6]) is asserted, EMSR bits 1-0 controls what mode the FIFO Level Counter is operating in. TABLE 12: SCRATCHPAD SWAP SELECTION
FCTR[6] EMSR[1] 0 1 1 1 1 X 0 0 1 1 EMSR[0] Scratchpad is X 0 1 0 1 Scratchpad RX FIFO Counter Mode TX FIFO Counter Mode RX FIFO Counter Mode Alternate RX/TX FIFO Counter Mode
During Alternate RX/TX FIFO Counter Mode, the first value read after EMSR bits 1-0 have been asserted will always be the RX FIFO Counter. The second value read will correspond with the TX FIFO Counter. The next value will be the RX FIFO Counter again, then the TX FIFO Counter and so on and so forth. EMSR[2]: Reserved EMSR[3]: Automatic RS485 Half-Duplex Control Output Inversion
* Logic 0 = RTS# output is a logic 0 during TX and a logic 1 during RX (default, compatible with 16C2850). * Logic 1 = RTS# output is a logic 1 during TX and a logic 0 during RX.
32
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
EMSR[5:4]: Extended RTS Hysteresis TABLE 13: RTS Hysteresis Levels
EMSR BIT-5 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 EMSR BIT-4 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 FCTR BIT-1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 FCTR BIT-0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 RTS# HYSTERESIS (CHARACTERS) 0 4 6 8 8 16 24 32 40 44 48 52 12 20 28 36
EMSR[6]: LSR Interrupt Mode
* Logic 0 = LSR Interrupt Delayed (for 16C2550 compatibility, default). LSR bits 2, 3, and 4 will generate an
interrupt when the character with the error is in the RHR.
* Logic 1 = LSR Interrupt Immediate. LSR bits 2, 3, and 4 will generate an interrupt as soon as the character is
received into the FIFO. EMSR[7]: 16X Sampling Rate Mode Logic 0 = 8X Sampling Rate. Logic 1 = 16X Sampling Rate (for 16C2550 compatibility, default). 4.13 FIFO Level Register (FLVL) - Read-Only The FIFO Level Register replaces the Scratchpad Register (during a Read) when FCTR[6] = 1. Note that this is not identical to the FIFO Data Count Register which can be accessed when LCR = 0xBF. FLVL[7:0]: FIFO Level Register This register provides the FIFO counter level for the RX FIFO or the TX FIFO or both depending on EMSR[1:0]. See Table 12 for details.
33
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO 4.14 Baud Rate Generator Registers (DLL and DLM) - Read/Write
xr
REV. 1.2.1
The concatenation of the contents of DLM and DLL gives the 16-bit divisor value which is used to calculate the baud rate:
* Baud Rate = (Clock Frequency / 16) / Divisor
See MCR bit-7 and the baud rate table also. 4.15 Device Identification Register (DVID) - Read Only This register contains the device ID (0x0A for XR16C2752). Prior to reading this register, DLL and DLM should be set to 0x00. 4.16 Device Revision Register (DREV) - Read Only This register contains the device revision information. For example, 0x01 means revision A. Prior to reading this register, DLL and DLM should be set to 0x00. 4.17 Trigger Level Register (TRG) - Write-Only User Programmable Transmit/Receive Trigger Level Register. TRG[7:0]: Trigger Level Register These bits are used to program desired trigger levels when trigger Table-D is selected. FCTR bit-7 selects between programming the RX Trigger Level (a logic 0) and the TX Trigger Level (a logic 1). 4.18 RX/TX FIFO Level Count Register (FC) - Read-Only This register is accessible when LCR = 0xBF. Note that this register is not identical to the FIFO Level Count Register which is located in the general register set when FCTR bit-6 = 1 (Scratchpad Register Swap). It is suggested to read the FIFO Level Count Register at the Scratchpad Register location when FCTR bit-6 = 1. See Table 12. FC[7:0]: RX/TX FIFO Level Count Receive/Transmit FIFO Level Count. Number of characters in Receiver FIFO (FCTR[7] = 0) or Transmitter FIFO (FCTR[7] = 1) can be read via this register. 4.19 Feature Control Register (FCTR) - Read/Write This register controls the XR16L2752 new functions. FCTR[1:0]: RTS Hysteresis User selectable RTS# hysteresis levels for hardware flow control application. After reset, these bits are set to "0" to select the next trigger level for hardware flow control. See Table 13 for more details. FCTR[2]: IrDa RX Inversion
* Logic 0 = Select RX input as encoded IrDa data. * Logic 1 = Select RX input as active high encoded IrDa data.
FCTR[3]: Auto RS-485 Direction Control
* Logic 0 = Standard ST16C550 mode. Transmitter generates an interrupt when transmit holding register
becomes empty and transmit shift register is shifting data out.
* Logic 1 = Enable Auto RS485 Direction Control function. The direction control signal, RTS# pin, changes its
output logic state from LOW to HIGH one bit time after the last stop bit of the last character is shifted out. Also, the Transmit interrupt generation is delayed until the transmitter shift register becomes empty. The RTS# output pin will automatically return LOW when a data byte is loaded into the TX FIFO. However, RTS# behavior can be inverted by setting EMSR[3] = 1.
34
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
FCTR[5:4]: Transmit/Receive Trigger Table Select See Table 10. TABLE 14: TRIGGER TABLE SELECT
FCTR BIT-5 0 0 1 1 FCTR BIT-4 0 1 0 1 TABLE Table-A (TX/RX) Table-B (TX/RX) Table-C (TX/RX) Table-D (TX/RX)
FCTR[6]: Scratchpad Swap
* Logic 0 = Scratch Pad register is selected as general read and write register. ST16C550 compatible mode. * Logic 1 = FIFO Count register (Read-Only), Enhanced Mode Select Register (Write-Only). Number of
characters in transmit or receive FIFO can be read via scratch pad register when this bit is set. Enhanced Mode Select Register is selected when it is written into. FCTR[7]: Programmable Trigger Register Select
* Logic 0 = Registers TRG and FC selected for RX. * Logic 1 = Registers TRG and FC selected for TX.
Enhanced Feature Register (EFR) Enhanced features are enabled or disabled using this register. Bit 0-3 provide single or dual consecutive character software flow control selection (see Table 15). When the Xon1 and Xon2 and Xoff1 and Xoff2 modes are selected, the double 8-bit words are concatenated into two sequential characters. Caution: note that whenever changing the TX or RX flow control bits, always reset all bits back to logic 0 (disable) before programming a new setting. EFR[3:0]: Software Flow Control Select Single character and dual sequential characters software flow control is supported. Combinations of software flow control can be selected by programming these bits.
35
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO TABLE 15: SOFTWARE FLOW CONTROL FUNCTIONS
EFR BIT-3 CONT-3 0 0 1 0 1 X X X 1 0 1 0 EFR BIT-2 CONT-2 0 0 0 1 1 X X X 0 1 1 0 EFR BIT-1 CONT-1 0 X X X X 0 1 0 1 1 1 1 EFR BIT-0 CONT-0 0 X X X X 0 0 1 1 1 1 1
xr
REV. 1.2.1
TRANSMIT AND RECEIVE SOFTWARE FLOW CONTROL No TX and RX flow control (default and reset) No transmit flow control Transmit Xon1, Xoff1 Transmit Xon2, Xoff2 Transmit Xon1 and Xon2, Xoff1 and Xoff2 No receive flow control Receiver compares Xon1, Xoff1 Receiver compares Xon2, Xoff2 Transmit Xon1, Xoff1 Receiver compares Xon1 or Xon2, Xoff1 or Xoff2 Transmit Xon2, Xoff2 Receiver compares Xon1 or Xon2, Xoff1 or Xoff2 Transmit Xon1 and Xon2, Xoff1 and Xoff2, Receiver compares Xon1 and Xon2, Xoff1 and Xoff2 No transmit flow control, Receiver compares Xon1 and Xon2, Xoff1 and Xoff2
EFR[4]: Enhanced Function Bits Enable Enhanced function control bit. This bit enables IER bits 4-7, ISR bits 4-5, FCR bits 4-5, and MCR bits 5-7 to be modified. After modifying any enhanced bits, EFR bit-4 can be set to a logic 0 to latch the new values. This feature prevents legacy software from altering or overwriting the enhanced functions once set. Normally, it is recommended to leave it enabled, logic 1.
* Logic 0 = modification disable/latch enhanced features. IER bits 4-7, ISR bits 4-5, FCR bits 4-5, and MCR
bits 5-7 are saved to retain the user settings. After a reset, the IER bits 4-7, ISR bits 4-5, FCR bits 4-5, and MCR bits 5-7 are set to a logic 0 to be compatible with ST16C550 mode (default).
* Logic 1 = Enables the above-mentioned register bits to be modified by the user.
EFR[5]: Special Character Detect Enable
* Logic 0 = Special Character Detect Disabled (default). * Logic 1 = Special Character Detect Enabled. The UART compares each incoming receive character with
data in Xoff-2 register. If a match exists, the receive data will be transferred to FIFO and ISR bit-4 will be set to indicate detection of the special character. Bit-0 corresponds with the LSB bit of the receive character. If flow control is set for comparing Xon1, Xoff1 (EFR [1:0]= `10') then flow control and special character work normally. However, if flow control is set for comparing Xon2, Xoff2 (EFR[1:0]= `01') then flow control works normally, but Xoff2 will not go to the FIFO, and will generate an Xoff interrupt and a special character interrupt, if enabled via IER bit-5.
36
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
EFR[6]: Auto RTS Flow Control Enable RTS# output may be used for hardware flow control by setting EFR bit-6 to logic 1. When Auto RTS is selected, an interrupt will be generated when the receive FIFO is filled to the programmed trigger level and RTS de-asserts HIGH at the next upper trigger level. RTS# will return LOW when FIFO data falls below the next lower trigger level. The RTS# output must be asserted (LOW) before the auto RTS can take effect. RTS# pin will function as a general purpose output when hardware flow control is disabled.
* Logic 0 = Automatic RTS flow control is disabled (default). * Logic 1 = Enable Automatic RTS flow control.
EFR[7]: Auto CTS Flow Control Enable Automatic CTS Flow Control.
* Logic 0 = Automatic CTS flow control is disabled (default). * Logic 1 = Enable Automatic CTS flow control. Data transmission stops when CTS# input de-asserts to logic
1. Data transmission resumes when CTS# returns to a logic 0. 4.20 Software Flow Control Registers (XOFF1, XOFF2, XON1, XON2) - Read/Write These registers are used as the programmable software flow control characters xoff1, xoff2, xon1, and xon2. For more details, see Table 6.
37
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO TABLE 16: UART RESET CONDITIONS FOR CHANNEL A AND B
REGISTERS DLM and DLL AFR RHR THR IER FCR ISR LCR MCR LSR MSR SPR EMSR FLVL EFR XON1 XON2 XOFF1 XOFF2 FC I/O SIGNALS TX OP1# MF# RTS# DTR# TXRDY# INT HIGH HIGH HIGH HIGH HIGH LOW LOW RESET STATE DLM = 0x00 and DLL = 0x01. Only resets to these values during a power up. They do not reset when the Reset Pin is asserted. Bits 7-0 = 0x00 Bits 7-0 = 0xXX Bits 7-0 = 0xXX Bits 7-0 = 0x00 Bits 7-0 = 0x00 Bits 7-0 = 0x01 Bits 7-0 = 0x00 Bits 7-0 = 0x00 Bits 7-0 = 0x60 Bits 3-0 = Logic 0 Bits 7-4 = Logic levels of the inputs inverted Bits 7-0 = 0xFF Bits 7-0 = 0x80 Bits 7-0 = 0x00 Bits 7-0 = 0x00 Bits 7-0 = 0x00 Bits 7-0 = 0x00 Bits 7-0 = 0x00 Bits 7-0 = 0x00 Bits 7-0 = 0x00 RESET STATE
xr
REV. 1.2.1
38
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
ABSOLUTE MAXIMUM RATINGS
Power Supply Range Voltage at Any Pin Operating Temperature Storage Temperature Package Dissipation 7 Volts GND-0.3 V to 7 V -40o to +85oC -65o to +150oC 500 mW
TYPICAL PACKAGE THERMAL RESISTANCE DATA (MARGIN OF ERROR: 15%)
Thermal Resistance (44-PLCC) theta-ja = 50oC/W, theta-jc = 21oC/W
ELECTRICAL CHARACTERISTICS
DC ELECTRICAL CHARACTERISTICS UNLESS OTHERWISE NOTED: TA=0O TO 70OC (-40O TO +85OC FOR INDUSTRIAL GRADE PACKAGE), VCC=2.25 -5.5V
SYMBOL VILCK VIHCK VIL VIH VOL PARAMETER Clock Input Low Level Clock Input High Level Input Low Voltage Input High Voltage Output Low Voltage 0.4 0.4 VOH Output High Voltage 2.0 1.8 IIL IIH CIN ICC ISLEEP Input Low Leakage Current Input High Leakage Current Input Pin Capacitance Power Supply Current Sleep Current 10 10 5 2.7 6 10 10 5 2.7 15 10 10 5 4 30 2.4 LIMITS 2.5V MIN MAX -0.3 2.0 -0.3 2.0 0.6 VCC 0.8 5.5 LIMITS 3.3V MIN MAX -0.3 2.4 -0.3 2.0 0.6 VCC 0.8 5.5 LIMITS 5.0V MIN MAX -0.5 3.0 -0.5 2.2 0.6 VCC 0.8 5.5 0.4 UNITS V V V V V V V V V V uA uA pF mA uA See Test 1 IOL = 6 mA IOL = 4 mA IOL = 2 mA IOH = -6 mA IOH = -1 mA IOH = -400 uA CONDITIONS
Test 1: The following inputs must remain steady at VCC or GND state to minimize Sleep current: A0-A2, D0D7, IOR#, IOW#, CS#, CHSEL, and all modem inputs. Also, RXA and RXB inputs must idle at logic 1 state while asleep. Floating inputs will result in sleep currents in the mA range. For PowerSave feature that isolates address, data and control signals, please see the XR16L2751 datasheet.
39
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
xr
REV. 1.2.1
AC ELECTRICAL CHARACTERISTICS UNLESS OTHERWISE NOTED: TA=0O TO 70OC (-40O TO +85OC FOR INDUSTRIAL GRADE PACKAGE), VCC=2.25-5.5V, 70 PF LOAD WHERE APPLICABLE
SYMBOL CLK OSC TAS TAH TCS TRD TDY TRDV TDD TWR TDY TDS TDH TWDO TMOD TRSI TSSI TRRI TSI TINT TWRI TSSR TRR TWT TSRT PARAMETER MIN Crystal Frequency External Clock Low/High Time External Clock Frequency Address Setup Time Address Hold Time Chip Select Width IOR# Strobe Width Read Cycle Delay Data Access Time Data Disable Time IOW# Strobe Width Write Cycle Delay Data Setup Time Data Hold Time Delay From IOW# To Output Delay To Set Interrupt From MODEM Input Delay To Reset Interrupt From IOR# Delay From Stop To Set Interrupt Delay From IOR# To Reset Interrupt Delay From Stop To Interrupt Delay From Initial INT Reset To Transmit Start Delay From IOW# To Reset Interrupt Delay From Stop To Set RXRDY# Delay From IOR# To Reset RXRDY# Delay From IOW# To Set TXRDY# Delay From Center of Start To Reset TXRDY# 8 0 150 150 25 15 150 150 150 1 150 150 24 150 1 150 150 8 8 10 10 150 150 150 135 45 0 75 75 20 10 75 75 75 1 75 75 24 75 1 75 75 8 8 20 24 10 10 75 75 75 70 30 0 50 50 15 10 50 50 50 1 50 50 24 50 1 50 50 8 LIMITS 2.5 MAX 16 15 33 10 10 50 50 50 45 30 MIN LIMITS 3.3 MAX 20 10 50 MIN LIMITS 5.0 MAX 24 MHz ns MHz ns ns ns ns ns ns ns ns ns ns ns ns ns ns Bclk ns ns Bclk ns Bclk ns ns Bclk UNIT
40
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
AC ELECTRICAL CHARACTERISTICS UNLESS OTHERWISE NOTED: TA=0O TO 70OC (-40O TO +85OC FOR INDUSTRIAL GRADE PACKAGE), VCC=2.25-5.5V, 70 PF LOAD WHERE APPLICABLE
SYMBOL TRST N Bclk PARAMETER MIN Reset Pulse Width Baud Rate Divisor Baud Clock 40 1 216-1 LIMITS 2.5 MAX MIN 40 1 216-1 LIMITS 3.3 MAX MIN 40 1 216-1 LIMITS 5.0 MAX ns Hz UNIT
16X or 8X of data rate
FIGURE 14. CLOCK TIMING
CLK EXTERNAL CLOCK OSC CLK
FIGURE 15. MODEM INPUT/OUTPUT TIMING FOR CHANNELS A & B
IO W # A c tiv e T W DO RTS# DTR# C h a n g e o f s ta te C h a n g e o f s ta te
CD# CTS# DSR# TMOD IN T
C h a n g e o f s ta te
C h a n g e o f s ta te T MOD
A c tiv e T RSI
A c tiv e
A c tiv e
IO R #
A c tiv e
A c tiv e
A c tiv e TMOD
R I#
C h a n g e o f s ta te
41
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO FIGURE 16. DATA BUS READ TIMING
xr
REV. 1.2.1
A0-A2 TAS
Valid Address TAS
Valid Address
TCS CSA#/ CSB#
TAH
TCS
TAH
TDY TRD IOR# TDD Valid Data TDD Valid Data TRD
TRDV D0-D7
TRDV
RDTm
FIGURE 17. DATA BUS WRITE TIMING
A0-A2 TAS
Valid Address TAH TAS
Valid Address TAH
TCS CSA#/ CSB#
TCS
TDY TWR IOW# TWR
TDS D0-D7 Valid Data
TDH
TDS Valid Data
TDH
16Write
42
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
FIGURE 18. RECEIVE READY & INTERRUPT TIMING [NON-FIFO MODE] FOR CHANNELS A & B
RX
Start Bit Stop Bit TSSR 1 Byte in RHR TSSR Active Data Ready TRR
D0:D7
D0:D7 TSSR 1 Byte in RHR TSSR Active Data Ready TRR
D0:D7 TSSR 1 Byte in RHR TSSR Active Data Ready TRR
INT
RXRDY#
IOR#
(Reading data out of RHR)
RXNFM
FIGURE 19. TRANSMIT READY & INTERRUPT TIMING [NON-FIFO MODE] FOR CHANNELS A & B
TX
Start Bit Stop Bit
(Unloading) IER[1] enabled
D0:D7
D0:D7
D0:D7
ISR is read
ISR is read
ISR is read
INT*
TWRI TSRT TWRI TSRT TWRI TSRT
TXRDY#
TWT
TWT
TWT
IOW#
(Loading data into THR)
*INT is cleared when the ISR is read or when data is loaded into the THR.
TXNonFIFO
43
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
xr
REV. 1.2.1
FIGURE 20. RECEIVE READY & INTERRUPT TIMING [FIFO MODE, DMA DISABLED] FOR CHANNELS A & B
Start Bit
RX
S D0:D7 Stop Bit
S D0:D7 T
D0:D7
TSSI
S D0:D7 T
S D0:D7 T S D0:D7 T
S D0:D7 T
RX FIFO drops below RX Trigger Level
INT
TSSR
RXRDY# First Byte is Received in RX FIFO IOR#
(Reading data out of RX FIFO)
RX FIFO fills up to RX Trigger Level or RX Data Timeout
FIFO Empties
TRRI
TRR
RXINTDMA#
FIGURE 21. RECEIVE READY & INTERRUPT TIMING [FIFO MODE, DMA ENABLED] FOR CHANNELS A & B
Start Bit Stop Bit S D0:D7 T
RX
S D0:D7
D0:D7
TSSI
S D0:D7 T
S D0:D7 T S D0:D7 T
S D0:D7 T
RX FIFO drops below RX Trigger Level
INT RX FIFO fills up to RX Trigger Level or RX Data Timeout RXRDY#
TSSR
FIFO Empties
TRRI
TRR
IOR#
(Reading data out of RX FIFO)
RXFIFODMA
44
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
FIGURE 22. TRANSMIT READY & INTERRUPT TIMING [FIFO MODE, DMA MODE DISABLED] FOR CHANNELS A & B
Start Bit Stop Bit Last Data Byte Transmitted S D0:D7 T S D0:D7 T TSI T S D0:D7 T S D0:D7 T ISR is read TSRT S D0:D7 T
TX FIFO Empty
TX
(Unloading) IER[1] enabled
S D0:D7 T ISR is read
INT*
TX FIFO fills up to trigger level TX FIFO drops below trigger level
TX FIFO Empty TWRI
TXRDY#
Data in TX FIFO
TWT
IOW#
(Loading data into FIFO)
*INT is cleared when the ISR is read or when TX FIFO fills up to the trigger level.
TXDMA#
FIGURE 23. TRANSMIT READY & INTERRUPT TIMING [FIFO MODE, DMA MODE ENABLED] FOR CHANNELS A & B
Start Bit Stop Bit Last Data Byte Transmitted D0:D7 S D0:D7 T S D0:D7 T S D0:D7 T S D0:D7 T ISR Read
TX
(Unloading) IER[1] enabled
S D0:D7 T S D0:D7 T ISR Read
TSRT
TSI
INT*
TX FIFO fills up to trigger level TWRI TX FIFO Full TX FIFO drops below trigger level At least 1 empty location in FIFO
TXRDY#
TWT
IOW#
(Loading data into FIFO)
*INT cleared when the ISR is read or when TX FIFO fills up to trigger level.
TXDMA
45
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
xr
REV. 1.2.1
PACKAGE DIMENSIONS (44 PIN PLCC)
44 LEAD PLASTIC LEADED CHIP CARRIER (PLCC)
Rev. 1.00
D D1 21 44 45 x H 2 45 x H 1 C Seating Plane A2
B1
D
D1
D3
B
D2
e
R D3 A1 A
Note: The control dimension is the millimeter column INCHES SYMBOL A A1 A2 B B1 C D D1 D2 D3 e H1 H2 R MIN 0.165 0.090 0.020 0.013 0.026 0.008 0.685 0.650 0.590 MAX 0.180 0.120 --0.021 0.032 0.013 0.695 0.656 0.630 MILLIMETERS MIN 4.19 2.29 0.51 0.33 0.66 0.19 17.40 16.51 14.99 MAX 4.57 3.05 --0.53 0.81 0.32 17.65 16.66 16.00
0.500 typ. 0.050 BSC 0.042 0.042 0.025 0.056 0.048 0.045
12.70 typ. 1.27 BSC 1.07 1.07 0.64 1.42 1.22 1.14
46
xr
REV. 1.2.1
XR16L2752 2.25V TO 5.5V DUART WITH 64-BYTE FIFO
REVISION HISTORY
DATE November 2001 March 2002 September 2002 REVISION Rev P1.0.0 Rev P1.1.0 Rev 1.0.0 Prelim data sheet. Corrected INTA/B pin descriptions and reset state. Renamed Sclk to Bclk. Changed A0-A7 in Figures 16 and 17 to A0-A2. Release into production. Clarified RTS# pin descriptions, XTAL1 pin description, external clock description, auto RS485 half-duplex control description, EMSR bit-3 description and updated 2.5 V, ICC and ISLEEP DC Electrical Characteristics. Updated AC Electrical Characteristics. Added Device Status to Ordering Information. Clarified pin descriptions- changed from using logic 1 and logic 0 to HIGH (VCC) and LOW (GND) for input and output pin descriptions. Updated the Data Access Time (TRDV) in AC Electrical Characteristics. Corrected reset state of MCR bit-3 in MFA# and MFB# pin descriptions. DESCRIPTION
March 2003 August 2004
Rev 1.1.0 Rev 1.2.0
May 2005
Rev 1.2.1
NOTICE EXAR Corporation reserves the right to make changes to the products contained in this publication in order to improve design, performance or reliability. EXAR Corporation assumes no responsibility for the use of any circuits described herein, conveys no license under any patent or other right, and makes no representation that the circuits are free of patent infringement. Charts and schedules contained here in are only for illustration purposes and may vary depending upon a user's specific application. While the information in this publication has been carefully checked; no responsibility, however, is assumed for inaccuracies. EXAR Corporation does not recommend the use of any of its products in life support applications where the failure or malfunction of the product can reasonably be expected to cause failure of the life support system or to significantly affect its safety or effectiveness. Products are not authorized for use in such applications unless EXAR Corporation receives, in writing, assurances to its satisfaction that: (a) the risk of injury or damage has been minimized; (b) the user assumes all such risks; (c) potential liability of EXAR Corporation is adequately protected under the circumstances. Copyright 2005 EXAR Corporation Datasheet May 2005. Send your UART technical inquiry with technical details to hotline: uarttechsupport@exar.com. Reproduction, in part or whole, without the prior written consent of EXAR Corporation is prohibited.
47
XR16L2752
REV. 1.2.1
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
xr
TABLE OF CONTENTS
GENERAL DESCRIPTION .................................................................................................1
APPLICATIONS................................................................................................................................................1 FEATURES .....................................................................................................................................................1
FIGURE 1. XR16L2752 BLOCK DIAGRAM ......................................................................................................................................... 1 FIGURE 2. PIN OUT ASSIGNMENT ..................................................................................................................................................... 2 ORDERING INFORMATION.................................................................................................................................2
PIN DESCRIPTIONS .........................................................................................................3
1.0 PRODUCT DESCRIPTION .....................................................................................................................6 2.0 FUNCTIONAL DESCRIPTIONS .............................................................................................................7
2.1 CPU INTERFACE .............................................................................................................................................. 7
FIGURE 3. XR16L2750 DATA BUS INTERCONNECTIONS .................................................................................................................... 7
2.2 2.3 2.4 2.5
5-VOLT TOLERANT INPUTS ........................................................................................................................... DEVICE RESET ................................................................................................................................................ DEVICE IDENTIFICATION AND REVISION ..................................................................................................... CHANNEL A AND B SELECTION ....................................................................................................................
7 7 7 7
TABLE 1: CHANNEL A AND B SELECT ............................................................................................................................................... 8
2.6 CHANNEL A AND B INTERNAL REGISTERS ................................................................................................ 8 2.7 SIMULTANEOUS WRITE TO CHANNEL A AND B ......................................................................................... 8 2.8 DMA MODE ....................................................................................................................................................... 8
TABLE 2: TXRDY# AND RXRDY# OUTPUTS IN FIFO AND DMA MODE............................................................................................. 8
2.9 INTA AND INTB OUTPUTS .............................................................................................................................. 9
TABLE 3: INTA AND INTB PINS OPERATION FOR TRANSMITTER ........................................................................................................ 9 TABLE 4: INTA AND INTB PIN OPERATION FOR RECEIVER ............................................................................................................... 9
2.10 CRYSTAL OSCILLATOR OR EXTERNAL CLOCK INPUT ........................................................................... 9
FIGURE 4. TYPICAL OSCILLATOR CONNECTIONS................................................................................................................................. 9 FIGURE 5. EXTERNAL CLOCK CONNECTION FOR EXTENDED DATA RATE .......................................................................................... 10
2.11 PROGRAMMABLE BAUD RATE GENERATOR ......................................................................................... 10
FIGURE 6. BAUD RATE GENERATOR AND PRESCALER ..................................................................................................................... 10 TABLE 5: TYPICAL DATA RATES WITH A 14.7456 MHZ CRYSTAL OR EXTERNAL CLOCK ...................................................................... 11
2.12 TRANSMITTER ............................................................................................................................................. 11
2.12.1 2.12.2 FIGURE 7. 2.12.3 FIGURE 8. TRANSMIT HOLDING REGISTER (THR) - WRITE ONLY ....................................................................................... 11 TRANSMITTER OPERATION IN NON-FIFO MODE ................................................................................................ 11 TRANSMITTER OPERATION IN NON-FIFO MODE .............................................................................................................. 12 TRANSMITTER OPERATION IN FIFO MODE ......................................................................................................... 12 TRANSMITTER OPERATION IN FIFO AND FLOW CONTROL MODE ..................................................................................... 12
2.13 RECEIVER .................................................................................................................................................... 12
2.13.1 RECEIVE HOLDING REGISTER (RHR) - READ-ONLY .......................................................................................... 13 FIGURE 9. RECEIVER OPERATION IN NON-FIFO MODE .................................................................................................................... 13 FIGURE 10. RECEIVER OPERATION IN FIFO AND AUTO RTS FLOW CONTROL MODE ....................................................................... 13
2.14 AUTO RTS (HARDWARE) FLOW CONTROL ............................................................................................. 14 2.15 AUTO RTS HYSTERESIS ............................................................................................................................ 14 2.16 AUTO CTS FLOW CONTROL ..................................................................................................................... 14
FIGURE 11. AUTO RTS AND CTS FLOW CONTROL OPERATION....................................................................................................... 15
2.17 AUTO XON/XOFF (SOFTWARE) FLOW CONTROL ................................................................................... 16
TABLE 6: AUTO XON/XOFF (SOFTWARE) FLOW CONTROL ............................................................................................................... 16
2.18 SPECIAL CHARACTER DETECT ............................................................................................................... 16 2.19 AUTO RS485 HALF-DUPLEX CONTROL .................................................................................................. 16 2.20 INFRARED MODE ........................................................................................................................................ 17
FIGURE 12. INFRARED TRANSMIT DATA ENCODING AND RECEIVE DATA DECODING .......................................................................... 17
2.21 2.22
SLEEP MODE WITH AUTO WAKE-UP ....................................................................................................... 18 INTERNAL LOOPBACK .............................................................................................................................. 19
FIGURE 13. INTERNAL LOOP BACK IN CHANNEL A AND B ................................................................................................................ 19
3.0 UART INTERNAL REGISTERS ...........................................................................................................20
TABLE 7: UART CHANNEL A AND B UART INTERNAL REGISTERS....................................................................................... 20 TABLE 8: INTERNAL REGISTERS DESCRIPTION. SHADED BITS ARE ENABLED WHEN EFR BIT-4=1......................................... 21
4.0 INTERNAL REGISTER DESCRIPTIONS .............................................................................................22
4.1 RECEIVE HOLDING REGISTER (RHR) - READ- ONLY ............................................................................... 22 4.2 TRANSMIT HOLDING REGISTER (THR) - WRITE-ONLY ............................................................................ 22 4.3 INTERRUPT ENABLE REGISTER (IER) - READ/WRITE .............................................................................. 22
I
xr
XR16L2752
REV. 1.2.1
2.25V TO 5.5V DUART WITH 64-BYTE FIFO
4.3.1 IER VERSUS RECEIVE FIFO INTERRUPT MODE OPERATION ............................................................................. 23 4.3.2 IER VERSUS RECEIVE/TRANSMIT FIFO POLLED MODE OPERATION................................................................ 23
4.4 INTERRUPT STATUS REGISTER (ISR) - READ-ONLY ............................................................................... 24
4.4.1 INTERRUPT GENERATION: ...................................................................................................................................... 24 4.4.2 INTERRUPT CLEARING: ........................................................................................................................................... 24 TABLE 9: INTERRUPT SOURCE AND PRIORITY LEVEL ....................................................................................................................... 25
4.5 FIFO CONTROL REGISTER (FCR) - WRITE-ONLY ..................................................................................... 25
TABLE 10: TRANSMIT AND RECEIVE FIFO TRIGGER TABLE AND LEVEL SELECTION .......................................................................... 27
4.6 LINE CONTROL REGISTER (LCR) - READ/WRITE ..................................................................................... 27
TABLE 11: PARITY SELECTION ........................................................................................................................................................ 28
4.7 ALTERNATE FUNCTION REGISTER (AFR) - READ/WRITE ....................................................................... 4.8 MODEM CONTROL REGISTER (MCR) OR GENERAL PURPOSE OUTPUTS CONTROL - READ/WRITE 4.9 LINE STATUS REGISTER (LSR) - READ ONLY ........................................................................................... 4.10 MODEM STATUS REGISTER (MSR) - READ ONLY .................................................................................. 4.11 SCRATCH PAD REGISTER (SPR) - READ/WRITE .................................................................................... 4.12 ENHANCED MODE SELECT REGISTER (EMSR) ...................................................................................... 4.13 4.14 4.15 4.16 4.17 4.18 4.19 FIFO LEVEL REGISTER (FLVL) - READ-ONLY ......................................................................................... BAUD RATE GENERATOR REGISTERS (DLL AND DLM) - READ/WRITE .............................................. DEVICE IDENTIFICATION REGISTER (DVID) - READ ONLY .................................................................... DEVICE REVISION REGISTER (DREV) - READ ONLY .............................................................................. TRIGGER LEVEL REGISTER (TRG) - WRITE-ONLY ................................................................................. RX/TX FIFO LEVEL COUNT REGISTER (FC) - READ-ONLY .................................................................... FEATURE CONTROL REGISTER (FCTR) - READ/WRITE ........................................................................
29 29 30 31 32 32 33 34 34 34 34 34 34
TABLE 12: SCRATCHPAD SWAP SELECTION .................................................................................................................................... 32 TABLE 13: RTS HYSTERESIS LEVELS ............................................................................................................................................. 33
TABLE 14: TRIGGER TABLE SELECT ............................................................................................................................................... 35 TABLE 15: SOFTWARE FLOW CONTROL FUNCTIONS ........................................................................................................................ 36
4.20 SOFTWARE FLOW CONTROL REGISTERS (XOFF1, XOFF2, XON1, XON2) - READ/WRITE ................ 37
TABLE 16: UART RESET CONDITIONS FOR CHANNEL A AND B............................................................................................ 38
ABSOLUTE MAXIMUM RATINGS .................................................................................. 39 TYPICAL PACKAGE THERMAL RESISTANCE DATA (MARGIN OF ERROR: 15%) 39 ELECTRICAL CHARACTERISTICS................................................................................ 39
DC ELECTRICAL CHARACTERISTICS.............................................................................................................. 39 AC ELECTRICAL CHARACTERISTICS.............................................................................................................. 40
Unless otherwise noted: TA=0o to 70oC (-40o to +85oC for industrial grade package), Vcc=2.25-5.5V, ................ 40 70 pF load where applicable ..................................................................................................................................... 40
FIGURE 14. FIGURE 15. FIGURE 16. FIGURE 17. FIGURE 19. FIGURE 18. FIGURE 20. FIGURE 21. FIGURE 22. FIGURE 23. CLOCK TIMING............................................................................................................................................................. 41 MODEM INPUT/OUTPUT TIMING FOR CHANNELS A & B ................................................................................................. 41 DATA BUS READ TIMING .............................................................................................................................................. 42 DATA BUS WRITE TIMING ............................................................................................................................................ 42 TRANSMIT READY & INTERRUPT TIMING [NON-FIFO MODE] FOR CHANNELS A & B ....................................................... 43 RECEIVE READY & INTERRUPT TIMING [NON-FIFO MODE] FOR CHANNELS A & B ......................................................... 43 RECEIVE READY & INTERRUPT TIMING [FIFO MODE, DMA DISABLED] FOR CHANNELS A & B........................................ 44 RECEIVE READY & INTERRUPT TIMING [FIFO MODE, DMA ENABLED] FOR CHANNELS A & B......................................... 44 TRANSMIT READY & INTERRUPT TIMING [FIFO MODE, DMA MODE DISABLED] FOR CHANNELS A & B ........................... 45 TRANSMIT READY & INTERRUPT TIMING [FIFO MODE, DMA MODE ENABLED] FOR CHANNELS A & B ............................ 45
PACKAGE DIMENSIONS (44 PIN PLCC) ....................................................................... 46
REVISION HISTORY ...................................................................................................................................... 47 TABLE OF CONTENTS ............................................................................................................ I
II


▲Up To Search▲   

 
Price & Availability of XR16L2752IJ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X